BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Arc Flash &amp; Electrical Power Training | Brainfiller - ECPv6.15.20//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://brainfiller.com
X-WR-CALDESC:Events for Arc Flash &amp; Electrical Power Training | Brainfiller
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Phoenix
BEGIN:STANDARD
TZOFFSETFROM:-0700
TZOFFSETTO:-0700
TZNAME:MST
DTSTART:20250101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Phoenix:20260427T080000
DTEND;TZID=America/Phoenix:20261105T170000
DTSTAMP:20260429T041404
CREATED:20170728T164748Z
LAST-MODIFIED:20260420T180405Z
UID:4369-1777276800-1793898000@brainfiller.com
SUMMARY:Medium Voltage Power Systems - 16 Hours
DESCRIPTION:"NFPA 70E requires \n				\n					retraining\n				\n					at intervals not to exceed 3 years"\n					\n						\n				\n				\n				\n									Retraining in safety-related work practices and applicable changes to NFPA 70E shall be performed at intervals not to exceed 3 years. This time frame is so employees can keep up to date with the triennial revision cycle of this important electrical safety standard. Jim Phillips\, P.E. takes you on a deep dive into the 2024 Edition of NFPA 70E with this two day class.  16 Hours | 16 PDHs | 1.6 | Available for On Site Training 								\n				\n				\n					\n				\n		\n					\n		\n				\n				\n					What You Will Receive with this Live Class:				\n				\n		\n		\n				\n				\n									16 Hours of On Site training by Jim Phillips\, P.E.In depth discussion of NFPA 70E 2024\, changes and electrical safety based on Jim’s 40+ years of experience.200+ page spiral bound notebook containing printed copies of over 400 slides.Ask questions during the class!								\n				\n				\n				\n									\n					\n						\n									About Jim Phillips\n					\n					\n				\n								\n				\n				\n				\n				\n				\n							\n			\n		\n						\n				\n				\n				\n					Preview Topics from this Live Class				\n				\n		\n		\n				\n				\n																\n															\n															\n				\n				\n		\n				\n				\n																\n															\n															\n				\n				\n		\n				\n				\n																\n															\n															\n				\n				\n				\n				\n				\n							\n			\n		\n						\n				\n				\n				\n							\n			\n						\n		\n						\n				\n				\n					\n				\n		\n					\n		\n		\n		\n				\n				\n					Attend this important NFPA 70E class \nby Jim Phillips\, P.E.				\n				\n				\n				\n									 								\n				\n				\n		\n				\n				\n				\n				\n							\n			\n						\n		\n						\n				\n				\n					\n				\n		\n					\n		\n				\n				\n					This 2 Day class covers topics from the 2024 Edition of  NFPA 70E such as:				\n				\n		\n		\n				\n				\n									Relocated DefinitionsUpdate Structure for Searchable Format 								\n				\n				\n		\n				\n				\n									Adding a Scope to many articles 								\n				\n				\n		\n				\n				\n									Global Changes such as adding “Electric” to Shock 								\n				\n				\n		\n				\n				\n									Normal Operation 7th condition added – Equipment rated for available fault current 								\n				\n				\n		\n				\n				\n									Emergency Response Plan added to Job Safety Planning 								\n				\n				\n				\n		\n		\n				\n				\n									120.5 (B)(2) Clarification regarding “Block or relieve stored non-electrical energy devices” 								\n				\n				\n		\n				\n				\n									120.6 “Test each phase conductor at each point of work” added to ESWC 								\n				\n				\n		\n				\n				\n									Harmonize Restricted Approach Boundaries with OSHA’s minimum approach distances 								\n				\n				\n		\n				\n				\n									130.5 (B) Clarification that doors do not provide enough protection from an arc flash (unless arc resistant) 								\n				\n				\n		\n				\n				\n									130.5(G) Informational Note provides examples of changes that could affect incident energy 								\n				\n				\n				\n		\n		\n				\n				\n									130.5(G) New text: labels shall be sufficient durability for environment 								\n				\n				\n		\n				\n				\n									Table 130.7(C)(15) (b) DC PPE Category Table  significantly revised 								\n				\n				\n		\n				\n				\n									320.3(A)(1) New thermal threshold added for battery safety 								\n				\n				\n		\n				\n				\n									NEW Informative Annex S – Assessing the Condition of Maintenance 								\n				\n				\n		\n				\n				\n									0.8 CEUs / 8 PDHs and a Certificate are included 								\n				\n				\n				\n				\n				\n							\n			\n		\n						\n				\n				\n					\n				\n		\n					\n		\n		\n		\n				\n				\n							\n					\n						\n				\n				\n				\n									\n					\n						\n									ABOUT JIM\n					\n					\n				\n								\n				\n				\n		\n				\n				\n									The instructor\, Jim Phillips is not just another trainer reading a script.   Jim’s training is based on his insider’s view from holding many leadership positions for the development of various electrical safety standards coupled with his arc flash testing experience and broad electrical power background.  This provides him a unique perspective from the inside – a perspective he loves sharing with others. When asked questions about some topics\, his explanations often run along the line of “Well\, here’s what happened in the lab when we blew it up…” Here is a sample of Jim’s involvement. ♦ Vice Chair – IEEE 1584 – IEEE Guide for Performing Arc Flash Calculations♦ Technical Committee Member – NFPA 70E Committee♦ International Chair – Geneva\, Switzerland based\,  IEC TC78 Live Working  40+ global standards including many for arc flash.♦ IEEE/NFPA Arc Flash Collaborative Research Project – Member of the Steering Committee♦ Author of Complete Guide to Performing Arc Flash Hazard Calculation Studies For a summary of the 2024 changes to NFPA 70E based on Jim’s article published in the multi-award winning Electrical Contractor Magazine. 								\n				\n				\n				\n									\n					\n						\n									2024 NFPA 70EChanges Article\n					\n					\n				\n								\n				\n				\n				\n				\n				\n							\n			\n						\n		\n						\n				\n				\n					\n				\n		\n					\n		\n				\n				\n									INTRODUCTION ELECTRICAL HAZARDSBurn Injury\, Respiratory Paralysis\, Ventricular Fibrillation\, “Just Curable” 2nd Degree Burns\, Arc Blast Pressure\, Sound Pressure\, Incident Energy  CODES AND STANDARDSOSHA 29 CFR – Part 1910\, Subpart S\, NFPA 70\, National Electrical Code®\, 2024 NFPA 70E\, Standard for Electrical Safety in the Workplace\, IEEE Standard 1584™\, IEEE Guide for Performing Arc Flash Hazard Calculations\, Legal Requirements\, Liability 2024 NFPA 70E REVISION PROCESS GLOBAL CHANGES “Electric” added to shock\, All sections have a scope\, Leather protectors are now just protectors ARTICLE 90 INTRODUCTIONReorganized and NEW Section for workplaces covered and not covered. NEW AND REVISED DEFINITIONSAll definitions moved to Article 100\, Terms structure modified for electronic searching ARTICLE 110 GENERAL REQUIRMENTS FOR ELECTRICAL SAFETY-RELATED WORK PRACTICES NEW SCOPE 110.1 REORGANIZATION (AGAIN)Consolidation of 110.1 through 110.4  into 110.2 NEW 110.2(B) WHEN REQUIRED – Electrically Safe Work Condition7th condition added to “normal operation” list. The equipment is rated for the available fault current.No evidence of impending failure – NEW Informational Note for evaluating water damaged electrical equipment. ELECTRICAL SAFETY PROGRAMGeneral\, Inspection\,  Awareness and Self Discipline\, Electrical Safety Program Principles\, Controls and Procedures\, Risk Assessment Procedure\, Job Safety Planning and Job Briefing\, Incident Investigation\, Auditing\, (NEW) Emergency Response Plan QUALIFIED PERSON Revised Text\, NFPA 70E Definition\, Trained and Knowledgeable Requirements\, Identifies Hazards  ARTICLE 120 ESTABLISHING AN ELECTRICALLY SAFE WORK CONDITION120.6 Text Added: “At each point of work” REVISION TO LOCKOUT DEVICE REQUIREMENTSNew addition to align NFPA 70E with OSHA language PROCESS FOR ESTABLISHING AND VERIFYING AN ELECTRICALLY SAFE WORK CONDITIONVerification Steps\, Methods Used\, PPE to be Worn During Procedure ARTICLE 130 WORK INVOLVING ELECTRICAL HAZARDSModifications to Tables 130.4(E)(a) and 130.4(E)(b) due to rounding and to harmonize with OSHA Minimum Approach Distances. New note added regarding elevation.Table 130.5(C) Equipment Condition changed to Operating Condition\, 130.5(G) New informational note regarding changes made by utilities or other entities.  ENERGIZED ELECTRICAL WORK PERMITPurpose of Permit\, When Required\, Data Required\, Approvals Process\,  SHOCK RISK ASSESSMENTOverview\, General\, Shock Risk Assessment\, Addition of Estimate of Likelihood and Severity Requirement\, Additional Protective Measures\, Shock PPE\, Documentation\, Shock Protection Boundaries\, Limited Approach Boundary\, Restricted Approach Boundary ARC FLASH RISK ASSESSMENTReorganization Overview\, General\, Estimate of Likelihood of Severity\, Arc Flash Risk Assessment\, Additional Protective Measures\, Documentation\, Arc Flash Boundary\, Arc Flash PPE\, Incident Energy Analysis Method\, IEEE 1584\, Effect of Arc Flash Duration\, Time Current Curves and Protective Devices\, Incident Energy and Distance\,  Selection of Arc Rated Clothing and PPE. Equipment Labeling\, Exception for No Detail on Labels. ARCING SHORT CIRCUIT CURRENT AND ARC DURATIONBasic concepts of short circuit current\, understanding arc duration and time-current curves ARC FLASH BOUNDARYAFB Definition\, Purpose\, How to Determine\, Work Within the Arc Flash Boundary NFPA 70E PPE CATEGORIESDefining the PPE Category using NFPA 70E Tables\, PPE Category 1\, 2\, 3\, 4 Requirements\, Limitations of Tables\, Using Calculations Instead\, PPE Category Tables for DC arc flash PERSONAL PROTECTIVE EQUIPMENTGeneral\, Care of Equipment\, Personal Protective Equipment\, Arc Rated Clothing\,  ASTM Testing\, Face Protection\, Hand Protection\, Foot Protection\, Head\, Face\, Neck and Chin Protection\, Eye and Hearing Protection\,  IEC Standards\, Revise Informational Note to 130.7(C)(1) Examples of Risk Reduction Methods. Revision to hearing protection requirements. Term “Gauntlet” is remove. ARC FLASH WARNING LABELSNEW Requirement – Label shall have sufficient durability. NFPA 70E Requirements\, ANSI Z535\, Signal Words\, Information to List on the Label\, Simplified Labeling Strategy\, Exception where specific information not required. OVERVIEW OF CHAPTERS TWO AND THREESummary of Major Topics\, Energy Thresholds added or revised for Article 320\, 330\, INFORMATIVE ANNEXESSummary of Informative Annexes\, Annex O Employee Safety-Related Design Concepts and Facility Owner Responsibilities – Addition of High-Impedance protected test points for voltage measurement through door. NEW Annex S Assessing the Condition of Maintenance 								\n				\n				\n				\n							\n			\n						\n		\n						\n				\n				\n					\n				\n		\n					\n		\n		\n		\n				\n				\n																														\n				\n				\n		\n				\n				\n					Why is NFPA 70E Such an Important Standard?				\n				\n				\n				\n									According to OSHA 1910.132(d) The employer is responsible to assess the hazards in the work place\, select\, have\, and use the correct Personal Protective Equipment (PPE) and document the assessment. The use of NFPA 70E and other related industry consensus standards has been used to demonstrate whether an employer acted reasonably when there is a possible OSHA enforcement action taken. So although NFPA 70E is not directly part of OSHA standards\, it can be used as evidence of whether an employer acted reasonably in complying with OSHA standards and addressing “recognized hazards”. There are more specific links within the OSHA standards as well. A typical example is found in 1910.335\, Safeguards for personnel protection which requires: “(a)(1)(i) Employees working in areas where there are potential electrical hazards shall be provided with\, and shall use\, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed.” This regulation requires that employees must be properly protected from potential electrical hazards\, by using adequate PPE\, but it does not provide specific detail of what specific personal protective equipment is necessary to achieve the objective. NFPA 70E is used to define the specific details and requirements.
URL:https://brainfiller.com/courses/medium-voltage-power-systems/
LOCATION:Streaming and On Location
CATEGORIES:Electrical Power Training,Scheduled Live Classes
ATTACH;FMTTYPE=image/jpeg:https://brainfiller.com/wp-content/uploads/2020/07/Medium-Voltage.jpg
END:VEVENT
END:VCALENDAR