{"id":2980,"date":"2016-09-29T03:00:00","date_gmt":"2016-09-29T10:00:00","guid":{"rendered":"https:\/\/brainfiller.com\/?p=2980"},"modified":"2025-11-19T09:02:59","modified_gmt":"2025-11-19T16:02:59","slug":"aluminum-vs-copper-ie-differences","status":"publish","type":"post","link":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/","title":{"rendered":"Diferencias entre IE de aluminio y cobre"},"content":{"rendered":"<p>Estoy leyendo el brillante libro \u201cIndustrial Power System Grounding Design Handbook\u201d de Dunki-Jacobs and Co. En \u00e9l, los autores indican que el cobre es endot\u00e9rmico (absorbe energ\u00eda al convertirse de s\u00f3lido a l\u00edquido) y el aluminio es exot\u00e9rmico (libera energ\u00eda al convertirse de s\u00f3lido a l\u00edquido).<\/p>\n<p>Afirman que debido a estas diferencias, los equipos con una construcci\u00f3n interna de aluminio tienen un potencial mucho mayor de liberaci\u00f3n de energ\u00eda destructiva durante una falla de arco en comparaci\u00f3n con la construcci\u00f3n de cobre. \u00bfAlguien tiene en cuenta esta diferencia en su an\u00e1lisis de los sistemas? El programa que uso para la evaluaci\u00f3n de arcos el\u00e9ctricos no me da una opci\u00f3n para bobinados de cobre frente a bobinas de aluminio en los transformadores de distribuci\u00f3n, por lo que no puedo comparar y contrastar los tipos de materiales para los niveles de IE. En el caso de los tableros de distribuci\u00f3n, tengo la capacidad de ajustar el tipo de material, pero no parece marcar una diferencia para los niveles de IE seg\u00fan un estudio de muestra r\u00e1pido que acabo de realizar.<\/p>\n<p>\u00bfQu\u00e9 opinas? \u00bfEs el tipo de material un factor que se debe tener en cuenta? Creo que la respuesta es no, pero me gustar\u00eda conocer la opini\u00f3n del grupo.<\/p>\n<p>Gracias,<br \/>\nBrian<\/p>\n<p><a href=\"http:\/\/www.arcflashforum.com\/viewtopic.php?p=19371&amp;sid=1c1c4d07cef1e884945c9caa4df1a5d6\" target=\"_blank\">LEER M\u00c1S.<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>I&#8217;m pushing through the brilliant book &#8220;Industrial Power System Grounding Design Handbook&#8221; by Dunki-Jacobs and Co. In it, the authors indicate that copper is endothermic (absorbs energy when converting from [&hellip;]<\/p>\n","protected":false},"author":63,"featured_media":46440,"comment_status":"open","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":""},"categories":[66,102],"tags":[125,126,127,13],"class_list":["post-2980","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arc-flash-forum-update","category-power-system-design","tag-electrical-power-system-grounding-design-handbook","tag-ie-differences","tag-ie-levels","tag-jim-phillips"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Aluminum vs. Copper IE differences - Arc Flash &amp; Electrical Power Training | Brainfiller<\/title>\n<meta name=\"description\" content=\"I&#039;m pushing through the brilliant book &quot;Industrial Power System Grounding Design Handbook&quot; by Dunki-Jacobs and Co. In it, the authors indicate that copper\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aluminum vs. Copper IE differences - Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"og:description\" content=\"I&#039;m pushing through the brilliant book &quot;Industrial Power System Grounding Design Handbook&quot; by Dunki-Jacobs and Co. In it, the authors indicate that copper\" \/>\n<meta property=\"og:url\" content=\"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/\" \/>\n<meta property=\"og:site_name\" content=\"Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400\" \/>\n<meta property=\"article:published_time\" content=\"2016-09-29T10:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-19T16:02:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"528\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Arc Flash Forum\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:site\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Arc Flash Forum\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/\"},\"author\":{\"name\":\"Arc Flash Forum\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/0703913f4f2a872aa6a494fcef87aa27\"},\"headline\":\"Aluminum vs. Copper IE differences\",\"datePublished\":\"2016-09-29T10:00:00+00:00\",\"dateModified\":\"2025-11-19T16:02:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/\"},\"wordCount\":184,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"keywords\":[\"Electrical Power System Grounding Design Handbook\",\"IE differences\",\"IE levels\",\"jim phillips\"],\"articleSection\":[\"Arc Flash Forum Update\",\"Power System Design\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/\",\"name\":\"Aluminum vs. Copper IE differences - Arc Flash &amp; Electrical Power Training | Brainfiller\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"datePublished\":\"2016-09-29T10:00:00+00:00\",\"dateModified\":\"2025-11-19T16:02:59+00:00\",\"description\":\"I'm pushing through the brilliant book \\\"Industrial Power System Grounding Design Handbook\\\" by Dunki-Jacobs and Co. In it, the authors indicate that copper\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#primaryimage\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"width\":800,\"height\":528},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/aluminum-vs-copper-ie-differences\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/brainfiller.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aluminum vs. Copper IE differences\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"name\":\"Arc Flash & Electrical Power Training | Brainfiller\",\"description\":\"Arc Flash &amp; Electrical Power Training by Jim Phillips\",\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/brainfiller.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\",\"name\":\"Brainfiller.com\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"width\":128,\"height\":118,\"caption\":\"Brainfiller.com\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/pages\\\/Brainfiller\\\/121692927901400\",\"https:\\\/\\\/x.com\\\/brainfiller\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/brainfiller\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/BrainfillerTV\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/0703913f4f2a872aa6a494fcef87aa27\",\"name\":\"Arc Flash Forum\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"caption\":\"Arc Flash Forum\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Aluminum vs. Copper IE differences - Arc Flash &amp; Electrical Power Training | Brainfiller","description":"I'm pushing through the brilliant book \"Industrial Power System Grounding Design Handbook\" by Dunki-Jacobs and Co. In it, the authors indicate that copper","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/","og_locale":"es_MX","og_type":"article","og_title":"Aluminum vs. Copper IE differences - Arc Flash &amp; Electrical Power Training | Brainfiller","og_description":"I'm pushing through the brilliant book \"Industrial Power System Grounding Design Handbook\" by Dunki-Jacobs and Co. In it, the authors indicate that copper","og_url":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/","og_site_name":"Arc Flash &amp; Electrical Power Training | Brainfiller","article_publisher":"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","article_published_time":"2016-09-29T10:00:00+00:00","article_modified_time":"2025-11-19T16:02:59+00:00","og_image":[{"width":800,"height":528,"url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","type":"image\/jpeg"}],"author":"Arc Flash Forum","twitter_card":"summary_large_image","twitter_creator":"@brainfiller","twitter_site":"@brainfiller","twitter_misc":{"Escrito por":"Arc Flash Forum","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#article","isPartOf":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/"},"author":{"name":"Arc Flash Forum","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/0703913f4f2a872aa6a494fcef87aa27"},"headline":"Aluminum vs. Copper IE differences","datePublished":"2016-09-29T10:00:00+00:00","dateModified":"2025-11-19T16:02:59+00:00","mainEntityOfPage":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/"},"wordCount":184,"commentCount":0,"publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"image":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","keywords":["Electrical Power System Grounding Design Handbook","IE differences","IE levels","jim phillips"],"articleSection":["Arc Flash Forum Update","Power System Design"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/","url":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/","name":"Aluminum vs. Copper IE differences - Arc Flash &amp; Electrical Power Training | Brainfiller","isPartOf":{"@id":"https:\/\/brainfiller.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#primaryimage"},"image":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","datePublished":"2016-09-29T10:00:00+00:00","dateModified":"2025-11-19T16:02:59+00:00","description":"I'm pushing through the brilliant book \"Industrial Power System Grounding Design Handbook\" by Dunki-Jacobs and Co. In it, the authors indicate that copper","breadcrumb":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#primaryimage","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","width":800,"height":528},{"@type":"BreadcrumbList","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/aluminum-vs-copper-ie-differences\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/brainfiller.com\/"},{"@type":"ListItem","position":2,"name":"Aluminum vs. Copper IE differences"}]},{"@type":"WebSite","@id":"https:\/\/brainfiller.com\/#website","url":"https:\/\/brainfiller.com\/","name":"Arc Flash & Electrical Power Training | Brainfiller","description":"Arc Flash &amp; Electrical Power Training by Jim Phillips","publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/brainfiller.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/brainfiller.com\/#organization","name":"Rellenador de cerebros.com","url":"https:\/\/brainfiller.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","width":128,"height":118,"caption":"Brainfiller.com"},"image":{"@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","https:\/\/x.com\/brainfiller","https:\/\/www.linkedin.com\/in\/brainfiller","https:\/\/www.youtube.com\/user\/BrainfillerTV"]},{"@type":"Person","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/0703913f4f2a872aa6a494fcef87aa27","name":"Foro sobre arcos el\u00e9ctricos","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","caption":"Arc Flash Forum"}}]}},"ticketed":false,"_links":{"self":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/2980","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/users\/63"}],"replies":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/comments?post=2980"}],"version-history":[{"count":0,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/2980\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media\/46440"}],"wp:attachment":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media?parent=2980"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/categories?post=2980"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/tags?post=2980"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}