{"id":3242,"date":"2016-11-21T11:22:25","date_gmt":"2016-11-21T18:22:25","guid":{"rendered":"https:\/\/brainfiller.com\/?p=3242"},"modified":"2025-11-21T14:24:52","modified_gmt":"2025-11-21T21:24:52","slug":"reducing-arc-flash-ie-at-fire-pump-controllers","status":"publish","type":"post","link":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/","title":{"rendered":"Reducci\u00f3n de la I\/E de arco el\u00e9ctrico en los controladores de bombas contra incendios"},"content":{"rendered":"<p><strong>Pregunta:<\/strong> \u00bfQu\u00e9 recomiendan ustedes para reducir los niveles de energ\u00eda incidente en los controladores de bombas contra incendios alimentados directamente desde el lado secundario de los transformadores de servicios p\u00fablicos?<\/p>\n<p><strong>Respuesta:\u00a0<\/strong>No se puede hacer. Esta es una pr\u00e1ctica com\u00fan pero es muy ilegal en la mayor\u00eda de los casos. El NEC es muy espec\u00edfico en cuanto a que se elimina la protecci\u00f3n contra sobrecargas (es decir, el rel\u00e9 de sobrecarga) y solo permanece la protecci\u00f3n contra cortocircuitos. No tengo idea de por qu\u00e9 y varios inspectores de bomberos han intentado decirme que las bombas contra incendios no tienen protecci\u00f3n alguna, lo cual es completamente falso. En la mayor\u00eda de los casos, la protecci\u00f3n contra cortocircuitos en el lado primario NO es suficiente para proteger el circuito derivado en el lado secundario. Y esa es la respuesta a su problema... la protecci\u00f3n contra cortocircuitos (por ejemplo, un MCP, tambi\u00e9n conocido como disyuntor solo magn\u00e9tico o simplemente un fusible) con el punto de disparo instant\u00e1neo establecido por debajo de la corriente de arco soluciona el problema y es legal seg\u00fan el 100%, y en la mayor\u00eda de los casos, como el que usted describe, donde es una gran violaci\u00f3n del C\u00f3digo, tambi\u00e9n soluciona ese problema. <a href=\"http:\/\/www.arcflashforum.com\/viewtopic.php?p=19544&amp;sid=cf70e8dac09c8a73c19f1fd16a024572\" target=\"_blank\">LEER M\u00c1S<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Question: What are you guys recommending to reduce incident energy levels on fire pump controllers fed directly from the secondary side of utility transformers? Answer:\u00a0Can&#8217;t be done. This is a [&hellip;]<\/p>\n","protected":false},"author":63,"featured_media":46440,"comment_status":"open","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":""},"categories":[99,66,419],"tags":[8,135,150,13,18],"class_list":["post-3242","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arc-flash","category-arc-flash-forum-update","category-nfpa-70e","tag-arc-flash","tag-arc-flash-safety","tag-fire-pump-controllers","tag-jim-phillips","tag-nec"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reducing Arc Flash I\/E At Fire Pump Controllers - Arc Flash &amp; Electrical Power Training | Brainfiller<\/title>\n<meta name=\"description\" content=\"Question: What are you guys recommending to reduce incident energy levels on fire pump controllers fed directly from the secondary side of utility\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reducing Arc Flash I\/E At Fire Pump Controllers - Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"og:description\" content=\"Question: What are you guys recommending to reduce incident energy levels on fire pump controllers fed directly from the secondary side of utility\" \/>\n<meta property=\"og:url\" content=\"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/\" \/>\n<meta property=\"og:site_name\" content=\"Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400\" \/>\n<meta property=\"article:published_time\" content=\"2016-11-21T18:22:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-21T21:24:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"528\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Arc Flash Forum\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:site\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Arc Flash Forum\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/\"},\"author\":{\"name\":\"Arc Flash Forum\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/0703913f4f2a872aa6a494fcef87aa27\"},\"headline\":\"Reducing Arc Flash I\\\/E At Fire Pump Controllers\",\"datePublished\":\"2016-11-21T18:22:25+00:00\",\"dateModified\":\"2025-11-21T21:24:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/\"},\"wordCount\":181,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"keywords\":[\"arc flash\",\"arc flash safety\",\"fire pump controllers\",\"jim phillips\",\"NEC\"],\"articleSection\":[\"Arc Flash\",\"Arc Flash Forum Update\",\"NFPA 70E\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/\",\"name\":\"Reducing Arc Flash I\\\/E At Fire Pump Controllers - Arc Flash &amp; Electrical Power Training | Brainfiller\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"datePublished\":\"2016-11-21T18:22:25+00:00\",\"dateModified\":\"2025-11-21T21:24:52+00:00\",\"description\":\"Question: What are you guys recommending to reduce incident energy levels on fire pump controllers fed directly from the secondary side of utility\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"width\":800,\"height\":528},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/reducing-arc-flash-ie-at-fire-pump-controllers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/brainfiller.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reducing Arc Flash I\\\/E At Fire Pump Controllers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"name\":\"Arc Flash & Electrical Power Training | Brainfiller\",\"description\":\"Arc Flash &amp; Electrical Power Training by Jim Phillips\",\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/brainfiller.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\",\"name\":\"Brainfiller.com\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"width\":128,\"height\":118,\"caption\":\"Brainfiller.com\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/pages\\\/Brainfiller\\\/121692927901400\",\"https:\\\/\\\/x.com\\\/brainfiller\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/brainfiller\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/BrainfillerTV\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/0703913f4f2a872aa6a494fcef87aa27\",\"name\":\"Arc Flash Forum\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"caption\":\"Arc Flash Forum\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reducing Arc Flash I\/E At Fire Pump Controllers - Arc Flash &amp; Electrical Power Training | Brainfiller","description":"Question: What are you guys recommending to reduce incident energy levels on fire pump controllers fed directly from the secondary side of utility","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/","og_locale":"es_MX","og_type":"article","og_title":"Reducing Arc Flash I\/E At Fire Pump Controllers - Arc Flash &amp; Electrical Power Training | Brainfiller","og_description":"Question: What are you guys recommending to reduce incident energy levels on fire pump controllers fed directly from the secondary side of utility","og_url":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/","og_site_name":"Arc Flash &amp; Electrical Power Training | Brainfiller","article_publisher":"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","article_published_time":"2016-11-21T18:22:25+00:00","article_modified_time":"2025-11-21T21:24:52+00:00","og_image":[{"width":800,"height":528,"url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","type":"image\/jpeg"}],"author":"Arc Flash Forum","twitter_card":"summary_large_image","twitter_creator":"@brainfiller","twitter_site":"@brainfiller","twitter_misc":{"Escrito por":"Arc Flash Forum","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#article","isPartOf":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/"},"author":{"name":"Arc Flash Forum","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/0703913f4f2a872aa6a494fcef87aa27"},"headline":"Reducing Arc Flash I\/E At Fire Pump Controllers","datePublished":"2016-11-21T18:22:25+00:00","dateModified":"2025-11-21T21:24:52+00:00","mainEntityOfPage":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/"},"wordCount":181,"commentCount":0,"publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"image":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","keywords":["arc flash","arc flash safety","fire pump controllers","jim phillips","NEC"],"articleSection":["Arc Flash","Arc Flash Forum Update","NFPA 70E"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/","url":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/","name":"Reducing Arc Flash I\/E At Fire Pump Controllers - Arc Flash &amp; Electrical Power Training | Brainfiller","isPartOf":{"@id":"https:\/\/brainfiller.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#primaryimage"},"image":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","datePublished":"2016-11-21T18:22:25+00:00","dateModified":"2025-11-21T21:24:52+00:00","description":"Question: What are you guys recommending to reduce incident energy levels on fire pump controllers fed directly from the secondary side of utility","breadcrumb":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#primaryimage","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","width":800,"height":528},{"@type":"BreadcrumbList","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/reducing-arc-flash-ie-at-fire-pump-controllers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/brainfiller.com\/"},{"@type":"ListItem","position":2,"name":"Reducing Arc Flash I\/E At Fire Pump Controllers"}]},{"@type":"WebSite","@id":"https:\/\/brainfiller.com\/#website","url":"https:\/\/brainfiller.com\/","name":"Arc Flash & Electrical Power Training | Brainfiller","description":"Arc Flash &amp; Electrical Power Training by Jim Phillips","publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/brainfiller.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/brainfiller.com\/#organization","name":"Rellenador de cerebros.com","url":"https:\/\/brainfiller.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","width":128,"height":118,"caption":"Brainfiller.com"},"image":{"@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","https:\/\/x.com\/brainfiller","https:\/\/www.linkedin.com\/in\/brainfiller","https:\/\/www.youtube.com\/user\/BrainfillerTV"]},{"@type":"Person","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/0703913f4f2a872aa6a494fcef87aa27","name":"Foro sobre arcos el\u00e9ctricos","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","caption":"Arc Flash Forum"}}]}},"ticketed":false,"_links":{"self":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/3242","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/users\/63"}],"replies":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/comments?post=3242"}],"version-history":[{"count":0,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/3242\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media\/46440"}],"wp:attachment":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media?parent=3242"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/categories?post=3242"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/tags?post=3242"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}