{"id":3463,"date":"2017-01-19T03:00:08","date_gmt":"2017-01-19T10:00:08","guid":{"rendered":"https:\/\/brainfiller.com\/?p=3463"},"modified":"2025-11-19T09:02:58","modified_gmt":"2025-11-19T16:02:58","slug":"af-label-service-disconnect-ats-enclosure","status":"publish","type":"post","link":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/","title":{"rendered":"Etiqueta AF en el desconectador de servicio y el ATS en el mismo gabinete"},"content":{"rendered":"<p>Conscientes de los riesgos de arco el\u00e9ctrico, muchos fabricantes gigantes no fabrican el interruptor de desconexi\u00f3n de servicio y el interruptor de transferencia autom\u00e1tica ubicados en la misma secci\u00f3n o gabinete. Sin embargo, esta pr\u00e1ctica se puede observar en el campo en cuadros el\u00e9ctricos con capacidad nominal de hasta 600 amperios.<br \/>\nLa parte peligrosa es que la parte anterior a la desconexi\u00f3n del servicio es como un punto ciego, ya que el \u00fanico dispositivo de protecci\u00f3n es el fusible de la empresa de servicios p\u00fablicos en el lado primario del transformador y, a menudo, da como resultado una alta energ\u00eda incidente (superior a 40 Cal\/cm2 en la mayor\u00eda de los casos) en la desconexi\u00f3n del servicio. Pero debido a la desconexi\u00f3n del servicio como dispositivo de protecci\u00f3n, en la parte posterior, la energ\u00eda incidente en el ATS (lado normal de la empresa de servicios p\u00fablicos) se reduce, por ejemplo, a menos de 4 cal\/cm2. El problema es que, aunque el ATS tiene una energ\u00eda incidente menor, se encuentra justo debajo de la desconexi\u00f3n del servicio en la misma secci\u00f3n (gabinete). Esto es un peligro de arco el\u00e9ctrico y coloco la etiqueta conservadora (desconexi\u00f3n del servicio) en la secci\u00f3n que tiene la desconexi\u00f3n del servicio en la parte superior y el ATS en la parte inferior. As\u00ed que, por favor, comparta sus ideas sobre c\u00f3mo colocar las etiquetas:<br \/>\n1. Cuando el Desconectador de Servicio y el ATS est\u00e1n ubicados en la misma secci\u00f3n (recinto)<br \/>\n2. Cuando existe una barrera entre el Desconectador de Servicio y el ATS ubicados en la misma secci\u00f3n (gabinete).<\/p>\n<p><a href=\"http:\/\/www.arcflashforum.com\/viewtopic.php?p=19633&amp;sid=d75a72f609bb997e5584efa824f5ed65\">LEER M\u00c1S<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>With the awareness of arc flash, many giant manufacturers do not manufacture the Service Disconnect and the Automatic Transfer Switch located in the same section or enclosure. However, this practice [&hellip;]<\/p>\n","protected":false},"author":63,"featured_media":46440,"comment_status":"open","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":""},"categories":[99,66],"tags":[8,141,153,177],"class_list":["post-3463","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arc-flash","category-arc-flash-forum-update","tag-arc-flash","tag-arc-flash-labels","tag-ats-protection","tag-service-disconnect"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>AF label on Service Disconnect and ATS in same Enclosure - Arc Flash &amp; Electrical Power Training | Brainfiller<\/title>\n<meta name=\"description\" content=\"With the awareness of arc flash, many giant manufacturers do not manufacture the Service Disconnect and the Automatic Transfer Switch located in the same\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AF label on Service Disconnect and ATS in same Enclosure - Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"og:description\" content=\"With the awareness of arc flash, many giant manufacturers do not manufacture the Service Disconnect and the Automatic Transfer Switch located in the same\" \/>\n<meta property=\"og:url\" content=\"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/\" \/>\n<meta property=\"og:site_name\" content=\"Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400\" \/>\n<meta property=\"article:published_time\" content=\"2017-01-19T10:00:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-19T16:02:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"528\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Arc Flash Forum\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:site\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Arc Flash Forum\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/\"},\"author\":{\"name\":\"Arc Flash Forum\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/0703913f4f2a872aa6a494fcef87aa27\"},\"headline\":\"AF label on Service Disconnect and ATS in same Enclosure\",\"datePublished\":\"2017-01-19T10:00:08+00:00\",\"dateModified\":\"2025-11-19T16:02:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/\"},\"wordCount\":224,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"keywords\":[\"arc flash\",\"arc flash labels\",\"ATS Protection\",\"service disconnect\"],\"articleSection\":[\"Arc Flash\",\"Arc Flash Forum Update\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/\",\"name\":\"AF label on Service Disconnect and ATS in same Enclosure - Arc Flash &amp; Electrical Power Training | Brainfiller\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"datePublished\":\"2017-01-19T10:00:08+00:00\",\"dateModified\":\"2025-11-19T16:02:58+00:00\",\"description\":\"With the awareness of arc flash, many giant manufacturers do not manufacture the Service Disconnect and the Automatic Transfer Switch located in the same\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#primaryimage\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"width\":800,\"height\":528},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/arc-flash-forum-update\\\/af-label-service-disconnect-ats-enclosure\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/brainfiller.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"AF label on Service Disconnect and ATS in same Enclosure\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"name\":\"Arc Flash & Electrical Power Training | Brainfiller\",\"description\":\"Arc Flash &amp; Electrical Power Training by Jim Phillips\",\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/brainfiller.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\",\"name\":\"Brainfiller.com\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"width\":128,\"height\":118,\"caption\":\"Brainfiller.com\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/pages\\\/Brainfiller\\\/121692927901400\",\"https:\\\/\\\/x.com\\\/brainfiller\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/brainfiller\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/BrainfillerTV\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/0703913f4f2a872aa6a494fcef87aa27\",\"name\":\"Arc Flash Forum\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g\",\"caption\":\"Arc Flash Forum\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AF label on Service Disconnect and ATS in same Enclosure - Arc Flash &amp; Electrical Power Training | Brainfiller","description":"With the awareness of arc flash, many giant manufacturers do not manufacture the Service Disconnect and the Automatic Transfer Switch located in the same","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/","og_locale":"es_MX","og_type":"article","og_title":"AF label on Service Disconnect and ATS in same Enclosure - Arc Flash &amp; Electrical Power Training | Brainfiller","og_description":"With the awareness of arc flash, many giant manufacturers do not manufacture the Service Disconnect and the Automatic Transfer Switch located in the same","og_url":"https:\/\/brainfiller.com\/es\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/","og_site_name":"Arc Flash &amp; Electrical Power Training | Brainfiller","article_publisher":"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","article_published_time":"2017-01-19T10:00:08+00:00","article_modified_time":"2025-11-19T16:02:58+00:00","og_image":[{"width":800,"height":528,"url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","type":"image\/jpeg"}],"author":"Arc Flash Forum","twitter_card":"summary_large_image","twitter_creator":"@brainfiller","twitter_site":"@brainfiller","twitter_misc":{"Escrito por":"Arc Flash Forum","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#article","isPartOf":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/"},"author":{"name":"Arc Flash Forum","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/0703913f4f2a872aa6a494fcef87aa27"},"headline":"AF label on Service Disconnect and ATS in same Enclosure","datePublished":"2017-01-19T10:00:08+00:00","dateModified":"2025-11-19T16:02:58+00:00","mainEntityOfPage":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/"},"wordCount":224,"commentCount":0,"publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"image":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","keywords":["arc flash","arc flash labels","ATS Protection","service disconnect"],"articleSection":["Arc Flash","Arc Flash Forum Update"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/","url":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/","name":"AF label on Service Disconnect and ATS in same Enclosure - Arc Flash &amp; Electrical Power Training | Brainfiller","isPartOf":{"@id":"https:\/\/brainfiller.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#primaryimage"},"image":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","datePublished":"2017-01-19T10:00:08+00:00","dateModified":"2025-11-19T16:02:58+00:00","description":"With the awareness of arc flash, many giant manufacturers do not manufacture the Service Disconnect and the Automatic Transfer Switch located in the same","breadcrumb":{"@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#primaryimage","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","width":800,"height":528},{"@type":"BreadcrumbList","@id":"https:\/\/brainfiller.com\/arc-flash-forum-update\/af-label-service-disconnect-ats-enclosure\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/brainfiller.com\/"},{"@type":"ListItem","position":2,"name":"AF label on Service Disconnect and ATS in same Enclosure"}]},{"@type":"WebSite","@id":"https:\/\/brainfiller.com\/#website","url":"https:\/\/brainfiller.com\/","name":"Arc Flash & Electrical Power Training | Brainfiller","description":"Arc Flash &amp; Electrical Power Training by Jim Phillips","publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/brainfiller.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/brainfiller.com\/#organization","name":"Rellenador de cerebros.com","url":"https:\/\/brainfiller.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","width":128,"height":118,"caption":"Brainfiller.com"},"image":{"@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","https:\/\/x.com\/brainfiller","https:\/\/www.linkedin.com\/in\/brainfiller","https:\/\/www.youtube.com\/user\/BrainfillerTV"]},{"@type":"Person","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/0703913f4f2a872aa6a494fcef87aa27","name":"Foro sobre arcos el\u00e9ctricos","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/db62b46c3a7c80cfbbd6b44b3793de4497c3ec9d6a66e622cb23052c175991fb?s=96&d=mm&r=g","caption":"Arc Flash Forum"}}]}},"ticketed":false,"_links":{"self":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/3463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/users\/63"}],"replies":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/comments?post=3463"}],"version-history":[{"count":0,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/3463\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media\/46440"}],"wp:attachment":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media?parent=3463"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/categories?post=3463"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/tags?post=3463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}