{"id":48500,"date":"2026-03-03T14:58:32","date_gmt":"2026-03-03T21:58:32","guid":{"rendered":"https:\/\/brainfiller.com\/?p=48500"},"modified":"2026-03-03T15:03:24","modified_gmt":"2026-03-03T22:03:24","slug":"impedance_grounding","status":"publish","type":"post","link":"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/","title":{"rendered":"Impedance Grounding and Arc Flash"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"48500\" class=\"elementor elementor-48500\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e40e448 e-con-full e-flex e-con e-parent\" data-id=\"e40e448\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-072f772 elementor-widget elementor-widget-text-editor\" data-id=\"072f772\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A short circuit happens when energized conductors accidentally make contact with each other and\/or to ground. When that connection forms, the load and its impedance is bypassed resulting usually resulting in a very high magnitude of current. There are several fault types\u2014three-phase, phase-to-phase, and line-to-ground, but the line-to-ground fault is by far the most common. You\u2019ll often see numbers in the 70\u201380% of all faults falling into this category. Some say this number is even higher.<\/p><p>Why so many line-to-ground faults? It\u2019s simple probability. Think about your car. Have you ever had all four tires go flat at the exact same time? It\u2019s possible, but it would take something unusual\u2014like driving through serious debris. Much more likely is losing one tire to wear or a nail as shown in <strong>Figure 1.<\/strong> (and yes, that has happened to me \u2013 more than once!)<\/p><p>Electrical systems behave the same way. Even though we have three energized phases, the odds of all three faulting simultaneously are relatively low. Three-phase faults usually require some outside influence\u2014like someone forgetting to remove temporary grounding jumpers, or heavy equipment such as a crane or backhoe making unintended contact. Most of the time, it\u2019s just one phase finding ground.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4ceedc5 e-grid e-con-boxed e-con e-child\" data-id=\"4ceedc5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4eee570 elementor-widget elementor-widget-image\" data-id=\"4eee570\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"737\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-NGR.jpg\" class=\"attachment-large size-large wp-image-48501\" alt=\"Flat Tire\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-NGR.jpg 985w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-NGR-300x276.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-NGR-768x707.jpg 768w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-NGR-13x12.jpg 13w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-NGR-360x331.jpg 360w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-NGR-600x552.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1. A Bad Day<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d0755ec elementor-widget elementor-widget-image\" data-id=\"d0755ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"738\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-1024x944.jpg\" class=\"attachment-large size-large wp-image-48502\" alt=\"Neutral Grounding Resistor\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-1024x944.jpg 1024w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-300x277.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-768x708.jpg 768w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-1536x1417.jpg 1536w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-13x12.jpg 13w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-360x332.jpg 360w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-600x553.jpg 600w, https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor.jpg 1866w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2. Neutral Grounding Resistor<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be284d3 elementor-widget elementor-widget-heading\" data-id=\"be284d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ground Faults and Arc Flash<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-add0ffd elementor-widget elementor-widget-text-editor\" data-id=\"add0ffd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Let&#8217;s face it. <a href=\"https:\/\/brainfiller.com\/es\/electrical-safety-codes-and-standards\/captain-murphy-dirty-harry-and-electrical-safety\/\">Things can go wrong<\/a> due to a wide variety of reasons. Ground faults don\u2019t always start as high magnitude currents. They can begin as low-level, intermittent arcing currents. In those cases, the standard phase overcurrent devices may not see enough current to trip quickly\u2014or at all. The result can be prolonged arcing and significant equipment damage.<\/p><p>At the other end of the spectrum, you can have a solid (bolted) ground fault with very high current. In that case, the phase overcurrent protection will almost certainly operate quickly. So ground faults can range from subtle and sneaky to violent and immediate.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6b7af0 elementor-widget elementor-widget-heading\" data-id=\"d6b7af0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Arc Flash - Escalation to Three-Phase<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-09c7b1f e-con-full e-flex e-con e-child\" data-id=\"09c7b1f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-00d9b60 e-con-full e-flex e-con e-child\" data-id=\"00d9b60\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9f6a74b elementor-widget elementor-widget-text-editor\" data-id=\"9f6a74b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>When current jumps an air gap between conductors, you get an arc flash. That arc produces intense heat, pressure waves, ultraviolet radiation, molten metal, and shrapnel. It\u2019s not just an electrical problem\u2014it\u2019s a serious safety hazard that I discuss in several of my <a href=\"https:\/\/brainfiller.com\/es\/learn\/all-courses\/\">training programs.<\/a><\/p><p>If an arc flash starts as a single line-to-ground event, it doesn\u2019t necessarily stay that way. The conducting plasma created by the arc can easily bridge to the second and third phases. When that happens, the event escalates into a three-phase arc flash.<\/p><p>And here\u2019s the key point: that escalation can happen in just a few cycles\u2014almost instantaneously. Can we predict when a single-phase arc will transition into three-phase? No. There\u2019s no reliable way to know. That\u2019s why arc flash incident energy calculations assume a three-phase condition. It\u2019s the conservative \/ worst case approach.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-478ff15 elementor-widget elementor-widget-heading\" data-id=\"478ff15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Puesta a tierra por impedancia<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccc7f36 elementor-widget elementor-widget-text-editor\" data-id=\"ccc7f36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>So what if we could stop a single-phase arc flash from developing significant energy in the first place? If the ground fault current is limited enough, there may not be sufficient energy to sustain or escalate the arc.<\/p><p>This is exactly what impedance grounding does\u2014typically by installing a neutral grounding resistor (NGR). An NGR is connected between the system neutral (such as the wye point of a transformer or generator) and the grounding electrode system as shown in <strong>Figure 2.<\/strong> Its job is to intentionally limit ground fault current to a controlled value.<\/p><p>The NEC lays out conditions for using a neutral grounding resistor. Sections 250.36 and 270.36 specify that:<\/p><ol><li>The system must be under conditions of maintenance and supervision so that only qualified personnel service it.<\/li><li>Ground detection equipment must be installed.<\/li><li>The system cannot supply line-to-neutral loads.<\/li><\/ol><p>These requirements ensure the system is properly monitored and maintained.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c557ca1 elementor-widget elementor-widget-heading\" data-id=\"c557ca1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">High-Resistance Grounding (HRG)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1543469 elementor-widget elementor-widget-text-editor\" data-id=\"1543469\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>High-resistance grounding is commonly used where uptime is critical. In an HRG system, the NGR is sized to limit ground fault current to a very low level\u2014typically between 1 and 10 amps.<\/p><p>At this current level, a single line-to-ground fault does not require an immediate shutdown. The system can continue operating while alarms and indicator lights alert personnel that a fault exists. Maintenance teams can then track down the issue and correct it, or schedule an orderly shutdown if needed.<\/p><p>That\u2019s a big deal for industrial processes. However, leaving a ground fault on the system indefinitely isn\u2019t a good idea. If a second ground fault occurs on another phase, you now have a phase-to-phase fault\u2014and that will result in a forced, and likely disruptive, shutdown.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-96254cc elementor-widget elementor-widget-heading\" data-id=\"96254cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Low-Resistance Grounding (LRG)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-515d641 elementor-widget elementor-widget-text-editor\" data-id=\"515d641\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Low-resistance grounding is more common on medium-voltage systems. At higher voltages, you often have significant capacitive charging current, especially when shielded cables are involved. The larger the distribution system and the more cable installed, the greater the total capacitance\u2014and therefore the higher the charging current.<\/p><p>In these situations, high-resistance grounding may not work well because the charging current that exists. Instead, a low-resistance grounding system is used.<\/p><p>With LRG, the resistor is sized to allow a higher ground fault current\u2014typically in the 100 to 1000 amp range. This level is intentionally set above the system\u2019s capacitive charging current so that protective devices such as relays can reliably detect and isolate the fault quickly.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-681437c elementor-widget elementor-widget-heading\" data-id=\"681437c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Safety Benefits of Impedance Grounding<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e060718 elementor-widget elementor-widget-text-editor\" data-id=\"e060718\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beyond equipment protection and system reliability, impedance grounding provides a major safety advantage and is one of the methods listed for <a href=\"https:\/\/brainfiller.com\/es\/electrical-safety-codes-and-standards\/safety-by-design-a-technique-that-incorporates-hazard-analysis-and-risk-assessment\/\">&#8220;safety by design&#8221;<\/a> By significantly limiting ground fault current\u2014especially in high-resistance grounded systems\u2014the energy available during a single-phase arc flash can be drastically reduced and almost eliminated in many cases.<\/p><p>If the ground fault current is low enough, the arc will likely not escalate into a three-phase event. In short, neutral grounding resistors aren\u2019t just about system performance\u2014they can play a critical role in reducing arc flash hazards and improving overall electrical safety.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7861b7b elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"7861b7b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-804c9a1 e-con-full five-three e-flex e-con e-child\" data-id=\"804c9a1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2bc78c4 elementor-widget elementor-widget-image\" data-id=\"2bc78c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"768\" height=\"512\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/11\/brainfiller-jim-vancouver-2019-1-768x512.jpg\" class=\"attachment-medium_large size-medium_large wp-image-40804\" alt=\"\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/11\/brainfiller-jim-vancouver-2019-1-768x512.jpg 768w, https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/11\/brainfiller-jim-vancouver-2019-1-300x200.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/11\/brainfiller-jim-vancouver-2019-1-600x400.jpg 600w, https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/11\/brainfiller-jim-vancouver-2019-1.jpg 900w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-feebb02 elementor-widget elementor-widget-image\" data-id=\"feebb02\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"475\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/12\/jim-brisbane-2023-1-768x475.jpg\" class=\"attachment-medium_large size-medium_large wp-image-42360\" alt=\"\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/12\/jim-brisbane-2023-1-768x475.jpg 768w, https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/12\/jim-brisbane-2023-1-300x186.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/12\/jim-brisbane-2023-1-18x12.jpg 18w, https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/12\/jim-brisbane-2023-1-600x371.jpg 600w, https:\/\/brainfiller.com\/wp-content\/uploads\/2024\/12\/jim-brisbane-2023-1.jpg 1000w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6ffe755 e-con-full e-flex e-con e-child\" data-id=\"6ffe755\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f2c64cc e-con-full e-flex e-con e-child\" data-id=\"f2c64cc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0213ad3 elementor-widget elementor-widget-text-editor\" data-id=\"0213ad3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Arc Flash and IEEE 1584 Leadership<\/h2><p>As <strong>Vice-Chair of IEEE 1584<\/strong>, Jim has played a major role in shaping the methodology behind modern <strong>arc-flash hazard calculations<\/strong>\u2014the backbone of NFPA 70E\u2019s incident energy analysis and PPE selection.<\/p><p>His instruction includes:<\/p><ul><li>Modeling techniques<\/li><li>Arcing current calculations<\/li><li>Incident energy evaluations<\/li><li>Arc-flash boundary determinations<\/li><li>Real-world mitigation strategies<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6d24b73 e-con-full e-flex e-con e-child\" data-id=\"6d24b73\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2309ae9 elementor-widget elementor-widget-image\" data-id=\"2309ae9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-768x1024.jpg\" class=\"attachment-large size-large wp-image-47076\" alt=\"Arc Flash investigation\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-768x1024.jpg 768w, https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-225x300.jpg 225w, https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-1152x1536.jpg 1152w, https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-1536x2048.jpg 1536w, https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-9x12.jpg 9w, https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-600x800.jpg 600w, https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/Arc-Flash-investigation-scaled.jpg 1920w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e49bea elementor-widget elementor-widget-text-editor\" data-id=\"2e49bea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>NFPA 70E Training Courses Available Through Brainfiller<\/h2>\nBrainfiller offers several courses designed and taught by Jim, all targeted to engineers, electricians, and safety professionals.<blockquote>\n<h3><a href=\"https:\/\/brainfiller.com\/es\/classes\/2024-nfpa-70e-changes-refresher-training-qualified-worker\/\">NFPA 70E Qualified Worker Training (8 hours)<\/a><\/h3>\nCovers risk assessment, PPE, LOTO, establishing an electrically safe work condition, and auditing requirements.\n<h3><a href=\"https:\/\/brainfiller.com\/es\/classes\/how-to-perform-an-arc-flash-study-2018-ieee-1584\/\">How to Perform an Arc-Flash Study | IEEE 1584 (16 hours)<\/a><\/h3>\nModeling, arcing current, incident energy, arc-flash boundaries, and system-level mitigation.\n<h3><a href=\"https:\/\/brainfiller.com\/es\/classes\/fundamentals-of-electrical-safety\/\">Fundamentals of Electrical Safety (2 hours)<\/a><\/h3>\nShock hazards, arc-flash basics, and the building blocks behind NFPA 70E.\n<h3><a href=\"https:\/\/brainfiller.com\/es\/classes\/fundamentals-of-dc-electrical-safety\/\">DC Electrical Safety Fundamentals (2 hours)<\/a><\/h3>\nKey safety practices for data centers and DC systems.\n<\/blockquote>\nAll training is available live, on-site, or on-demand, and includes completion certificates with CEU\/PDH documentation.\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-646c185 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"646c185\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/es\/learn\/all-courses\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Explore NFPA 70E Training Courses on Brainfiller<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>A short circuit happens when energized conductors accidentally make contact with each other and\/or to ground. When that connection forms, the load and its impedance is bypassed resulting usually resulting [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":48502,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"Tribe__Tickets_Plus__Commerce__WooCommerce__Main","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":""},"categories":[9,404],"tags":[],"class_list":["post-48500","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arc-flash-electrical-safety","category-electrical-power-system-design-and-analysis"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Impedance Grounding and Arc Flash - Arc Flash &amp; Electrical Power Training | Brainfiller<\/title>\n<meta name=\"description\" content=\"A short circuit happens when energized conductors accidentally make contact with each other and\/or to ground. When that connection forms, the load and its\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Impedance Grounding and Arc Flash - Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"og:description\" content=\"A short circuit happens when energized conductors accidentally make contact with each other and\/or to ground. When that connection forms, the load and its\" \/>\n<meta property=\"og:url\" content=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/\" \/>\n<meta property=\"og:site_name\" content=\"Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400\" \/>\n<meta property=\"article:author\" content=\"Jim Phillips \/ Brainfiller.com\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-03T21:58:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-03T22:03:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-1024x944.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"944\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Jim Phillips\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:site\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jim Phillips\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/\"},\"author\":{\"name\":\"Jim Phillips\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/03247835e81df659321c6b756e0389e5\"},\"headline\":\"Impedance Grounding and Arc Flash\",\"datePublished\":\"2026-03-03T21:58:32+00:00\",\"dateModified\":\"2026-03-03T22:03:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/\"},\"wordCount\":1150,\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/26-03-03-Ground-Resistor.jpg\",\"articleSection\":[\"Arc Flash and Electrical Safety\",\"Electrical Power System Design and Analysis\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/\",\"name\":\"Impedance Grounding and Arc Flash - Arc Flash &amp; Electrical Power Training | Brainfiller\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/26-03-03-Ground-Resistor.jpg\",\"datePublished\":\"2026-03-03T21:58:32+00:00\",\"dateModified\":\"2026-03-03T22:03:24+00:00\",\"description\":\"A short circuit happens when energized conductors accidentally make contact with each other and\\\/or to ground. When that connection forms, the load and its\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/#primaryimage\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/26-03-03-Ground-Resistor.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/26-03-03-Ground-Resistor.jpg\",\"width\":1866,\"height\":1721,\"caption\":\"Neutral Grounding Resistor\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/impedance_grounding\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/brainfiller.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Impedance Grounding and Arc Flash\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"name\":\"Arc Flash & Electrical Power Training | Brainfiller\",\"description\":\"Arc Flash &amp; Electrical Power Training by Jim Phillips\",\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/brainfiller.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\",\"name\":\"Brainfiller.com\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"width\":128,\"height\":118,\"caption\":\"Brainfiller.com\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/pages\\\/Brainfiller\\\/121692927901400\",\"https:\\\/\\\/x.com\\\/brainfiller\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/brainfiller\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/BrainfillerTV\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/03247835e81df659321c6b756e0389e5\",\"name\":\"Jim Phillips\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g\",\"caption\":\"Jim Phillips\"},\"description\":\"It's an epic saga....\",\"sameAs\":[\"Jim Phillips \\\/ Brainfiller.com\",\"https:\\\/\\\/x.com\\\/brainfiller\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Impedance Grounding and Arc Flash - Arc Flash &amp; Electrical Power Training | Brainfiller","description":"A short circuit happens when energized conductors accidentally make contact with each other and\/or to ground. When that connection forms, the load and its","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/","og_locale":"es_MX","og_type":"article","og_title":"Impedance Grounding and Arc Flash - Arc Flash &amp; Electrical Power Training | Brainfiller","og_description":"A short circuit happens when energized conductors accidentally make contact with each other and\/or to ground. When that connection forms, the load and its","og_url":"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/","og_site_name":"Arc Flash &amp; Electrical Power Training | Brainfiller","article_publisher":"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","article_author":"Jim Phillips \/ Brainfiller.com","article_published_time":"2026-03-03T21:58:32+00:00","article_modified_time":"2026-03-03T22:03:24+00:00","og_image":[{"width":1024,"height":944,"url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor-1024x944.jpg","type":"image\/jpeg"}],"author":"Jim Phillips","twitter_card":"summary_large_image","twitter_creator":"@brainfiller","twitter_site":"@brainfiller","twitter_misc":{"Escrito por":"Jim Phillips","Tiempo de lectura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/#article","isPartOf":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/"},"author":{"name":"Jim Phillips","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/03247835e81df659321c6b756e0389e5"},"headline":"Impedance Grounding and Arc Flash","datePublished":"2026-03-03T21:58:32+00:00","dateModified":"2026-03-03T22:03:24+00:00","mainEntityOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/"},"wordCount":1150,"publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor.jpg","articleSection":["Arc Flash and Electrical Safety","Electrical Power System Design and Analysis"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/","url":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/","name":"Impedance Grounding and Arc Flash - Arc Flash &amp; Electrical Power Training | Brainfiller","isPartOf":{"@id":"https:\/\/brainfiller.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/#primaryimage"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor.jpg","datePublished":"2026-03-03T21:58:32+00:00","dateModified":"2026-03-03T22:03:24+00:00","description":"A short circuit happens when energized conductors accidentally make contact with each other and\/or to ground. When that connection forms, the load and its","breadcrumb":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/#primaryimage","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2026\/03\/26-03-03-Ground-Resistor.jpg","width":1866,"height":1721,"caption":"Neutral Grounding Resistor"},{"@type":"BreadcrumbList","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/impedance_grounding\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/brainfiller.com\/"},{"@type":"ListItem","position":2,"name":"Impedance Grounding and Arc Flash"}]},{"@type":"WebSite","@id":"https:\/\/brainfiller.com\/#website","url":"https:\/\/brainfiller.com\/","name":"Arc Flash & Electrical Power Training | Brainfiller","description":"Arc Flash &amp; Electrical Power Training by Jim Phillips","publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/brainfiller.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/brainfiller.com\/#organization","name":"Rellenador de cerebros.com","url":"https:\/\/brainfiller.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","width":128,"height":118,"caption":"Brainfiller.com"},"image":{"@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","https:\/\/x.com\/brainfiller","https:\/\/www.linkedin.com\/in\/brainfiller","https:\/\/www.youtube.com\/user\/BrainfillerTV"]},{"@type":"Person","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/03247835e81df659321c6b756e0389e5","name":"Jim Phillips","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g","caption":"Jim Phillips"},"description":"It's an epic saga....","sameAs":["Jim Phillips \/ Brainfiller.com","https:\/\/x.com\/brainfiller"]}]}},"ticketed":false,"_links":{"self":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/48500","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/comments?post=48500"}],"version-history":[{"count":0,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/48500\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media\/48502"}],"wp:attachment":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media?parent=48500"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/categories?post=48500"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/tags?post=48500"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}