{"id":5269,"date":"2018-01-15T12:08:17","date_gmt":"2018-01-15T19:08:17","guid":{"rendered":"https:\/\/brainfiller.com\/?p=5269"},"modified":"2025-11-21T14:24:51","modified_gmt":"2025-11-21T21:24:51","slug":"arc-flash-labels-exception2","status":"publish","type":"post","link":"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/","title":{"rendered":"Etiquetas de arco el\u00e9ctrico: informaci\u00f3n que ya no es necesaria (tal vez)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5269\" class=\"elementor elementor-5269\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-de18f73 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"de18f73\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5c70487\" data-id=\"5c70487\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ca60f63 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"ca60f63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1b32e444 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1b32e444\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-290259f\" data-id=\"290259f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-54c897d9 elementor-widget elementor-widget-text-editor\" data-id=\"54c897d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong><a href=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2018\/01\/Label-No-Detals.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-5274 alignleft\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2018\/01\/Label-No-Detals.jpg\" alt=\"New Label Exception\" width=\"370\" height=\"252\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2018\/01\/Label-No-Detals.jpg 877w, https:\/\/brainfiller.com\/wp-content\/uploads\/2018\/01\/Label-No-Detals-600x408.jpg 600w, https:\/\/brainfiller.com\/wp-content\/uploads\/2018\/01\/Label-No-Detals-300x204.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2018\/01\/Label-No-Detals-768x523.jpg 768w\" sizes=\"(max-width: 370px) 100vw, 370px\" \/><\/a>Nueva excepci\u00f3n 130.5(H) Excepci\u00f3n n.\u00b0 2: Es posible que no se requiera informaci\u00f3n en la etiqueta sobre peligro de arco el\u00e9ctrico.<\/strong><\/p><p>Es sorprendente c\u00f3mo han evolucionado los requisitos para el etiquetado de arcos el\u00e9ctricos con cada nueva edici\u00f3n de la norma NFPA 70E. Conocidas como etiquetas de advertencia de arcos el\u00e9ctricos seg\u00fan el C\u00f3digo El\u00e9ctrico Nacional y etiquetas de equipos seg\u00fan la norma NFPA 70E 130.5(H), la mayor\u00eda de las personas simplemente se refieren a ellas como etiquetas de arcos el\u00e9ctricos.<\/p><p>Lo que comenz\u00f3 como un simple requisito para advertir a las personas sobre el peligro de arco el\u00e9ctrico, se ha transformado en una lista de Requisitos de Etiquetas de Arco El\u00e9ctrico de la NFPA 70E que se encuentran en la NFPA 70E 130.5(H). Como ejemplo, la evoluci\u00f3n de los requisitos de las etiquetas (a veces denominadas calcoman\u00edas de arco el\u00e9ctrico) fue la informaci\u00f3n para ayudar a seleccionar Equipo de Protecci\u00f3n Personal y Ropa con Clasificaci\u00f3n de Arco El\u00e9ctrico. En el pasado, los requisitos comenzaron con Tablas de Categor\u00edas de Riesgo de Peligro, luego se pas\u00f3 a utilizar las Tablas de Categor\u00edas de Riesgo de Peligro O la energ\u00eda del incidente calculada. Hoy, la Tabla de Categor\u00edas de Riesgo de Peligro es ahora la Tabla de Categor\u00edas de EPP y hay una variedad de opciones enumeradas en 130.5(H). Otra evoluci\u00f3n fue con el t\u00e9rmino originalmente conocido como L\u00edmite de Protecci\u00f3n de Arco El\u00e9ctrico. M\u00e1s tarde se cambi\u00f3 a L\u00edmite de Protecci\u00f3n de Arco El\u00e9ctrico y finalmente a L\u00edmite de Arco El\u00e9ctrico. Es interesante mirar las etiquetas hoy y ver qu\u00e9 t\u00e9rmino se est\u00e1 utilizando. Todav\u00eda se ven algunos de los t\u00e9rminos anteriores, pero independientemente de la terminolog\u00eda, el l\u00edmite del arco el\u00e9ctrico sigue siendo la distancia (l\u00edmite de aproximaci\u00f3n) desde una fuente de arco donde la energ\u00eda incidente es de 1,2 calor\u00edas\/cent\u00edmetro.<sup>2<\/sup> \u00a0(calor\u00edas\/cm<sup>2<\/sup>). Este l\u00edmite es para el caso en que existe peligro de arco el\u00e9ctrico.<\/p><p>Avanzamos r\u00e1pidamente hasta la edici\u00f3n 2018 de NFPA 70E y se ha agregado otro cambio a los requisitos de etiquetado. \u00a1La excepci\u00f3n n.\u00b0 2 de 130.5(H) ahora permite eliminar la informaci\u00f3n detallada de la etiqueta de arco el\u00e9ctrico!<\/p><h3 style=\"text-align: center;\"><span style=\"color: #ff6600;\"><strong>\u00bf\u00a1No hay informaci\u00f3n en la etiqueta?!?!! <\/strong><strong>\u00bfQu\u00e9? \u00bfEh? \u00bfEst\u00e1s bromeando?<\/strong><\/span><\/h3><p>No estoy bromeando y adem\u00e1s, el D\u00eda de los Inocentes est\u00e1 a m\u00e1s de dos meses de distancia.<\/p><p>El texto exacto de la nueva Excepci\u00f3n N\u00ba 2 es:<\/p><p><em>En instalaciones industriales supervisadas donde las condiciones de mantenimiento y supervisi\u00f3n de ingenier\u00eda garantizan que solo personas calificadas monitorean y dan servicio al sistema, se permitir\u00e1 que la informaci\u00f3n requerida en 130.5(H)(1) a 130.5(H)(3) se documente de una manera que est\u00e9 f\u00e1cilmente disponible para las personas que probablemente realicen el examen, servicio, mantenimiento y operaci\u00f3n del equipo mientras est\u00e9 energizado.<\/em><\/p><p>130.5 H(1) a (H)(3) son los siguientes:<\/p><ul><li>(H)(1) Voltaje nominal del sistema<\/li><li>(H)(2) L\u00edmite de arco el\u00e9ctrico<\/li><li>(H)(3) Enumere al menos uno de los siguientes: Energ\u00eda incidente disponible y la distancia de trabajo correspondiente o la categor\u00eda de EPP contra arco el\u00e9ctrico, clasificaci\u00f3n m\u00ednima de arco de la ropa, nivel de EPP espec\u00edfico del sitio.<\/li><\/ul><p>Esta nueva excepci\u00f3n puede ser uno de esos proverbiales \u201cdisparos que se oyen en todo el mundo\u201d, as\u00ed que veamos los detalles. En primer lugar, para poder utilizar esta excepci\u00f3n, se deben cumplir varias condiciones, entre las que se incluyen los siguientes t\u00e9rminos.<\/p><p><strong>Instalaci\u00f3n industrial supervisada:<\/strong> Aunque NFPA 70E no define este t\u00e9rmino, se considera una instalaci\u00f3n con una carga utilizada en procesos industriales, actividades de fabricaci\u00f3n o ambos y se abordan t\u00e9rminos adicionales a continuaci\u00f3n.<\/p><p><strong>Condiciones de mantenimiento<\/strong>:La edici\u00f3n 2018 de NFPA 70E agreg\u00f3 una nueva definici\u00f3n para \u201cCondici\u00f3n de mantenimiento\u201d, que es el estado del equipo el\u00e9ctrico considerando las instrucciones y recomendaciones de los fabricantes y los c\u00f3digos, est\u00e1ndares y pr\u00e1cticas recomendadas de la industria aplicables.<\/p><p><strong>Supervisi\u00f3n de ingenier\u00eda:<\/strong> Este es otro t\u00e9rmino que no est\u00e1 definido espec\u00edficamente; sin embargo, generalmente se considera que hay una o m\u00e1s personas de ingenier\u00eda calificadas disponibles para la supervisi\u00f3n.<\/p><p><strong>Persona calificada:<\/strong> Seg\u00fan la definici\u00f3n de NFPA 70E, una persona calificada es aquella que ha demostrado habilidades y conocimientos relacionados con la construcci\u00f3n y operaci\u00f3n de equipos e instalaciones el\u00e9ctricas y ha recibido capacitaci\u00f3n en seguridad para identificar los peligros y reducir el riesgo asociado.<\/p><p><strong>Documentado:<\/strong> La documentaci\u00f3n a la que se hace referencia para (H)(1) a (H)(3) podr\u00eda adoptar la forma de un informe de estudio de arco el\u00e9ctrico. Esto es similar a un estudio de cortocircuito en el que, a excepci\u00f3n de algunos requisitos del C\u00f3digo El\u00e9ctrico Nacional (NEC), los valores calculados a partir del estudio normalmente no se incluyen en el equipo, sino que se documentan en un informe.<\/p><h3><strong>Configuraciones: un objetivo en movimiento<\/strong><\/h3><p>\u00bfPor qu\u00e9 el cambio repentino en la filosof\u00eda de etiquetado? Es de conocimiento com\u00fan que los sistemas de energ\u00eda industrial a menudo no se limitan a una sola configuraci\u00f3n operativa. M\u00faltiples fuentes, enlaces, generadores, la lista contin\u00faa. Debido a los requisitos de proceso y mantenimiento y al mantenimiento del funcionamiento durante fallas del equipo, a veces puede ser necesario reconfigurar el sistema de energ\u00eda y el estudio de arco el\u00e9ctrico fue un intento de alcanzar un objetivo en movimiento: la configuraci\u00f3n del sistema.<\/p><p>Con cada reconfiguraci\u00f3n, la corriente de falla disponible y, posiblemente, los tiempos de operaci\u00f3n del dispositivo de protecci\u00f3n pueden cambiar, lo que genera un l\u00edmite de arco el\u00e9ctrico y energ\u00eda incidente diferente. Antes de la incorporaci\u00f3n de esta nueva excepci\u00f3n, generalmente solo hab\u00eda dos opciones disponibles para esta situaci\u00f3n:<\/p><ul><li>Instalar m\u00faltiples etiquetas para diferentes configuraciones o<\/li><li>Utilice el peor escenario posible.<\/li><\/ul><p>Cada opci\u00f3n tiene sus desventajas. El uso de varias etiquetas puede generar confusi\u00f3n y el uso del peor escenario posible puede llevar a requerir EPP con una clasificaci\u00f3n de arco m\u00e1s alta que la necesaria para la configuraci\u00f3n normal, lo que normalmente no es deseable para el trabajador si no es necesario.<\/p><p>Esta nueva excepci\u00f3n proporciona un m\u00e9todo para sistemas industriales que cumplen con los estrictos requisitos delineados en la nueva excepci\u00f3n para garantizar que las personas calificadas tengan la informaci\u00f3n correcta en funci\u00f3n de la configuraci\u00f3n espec\u00edfica.<\/p><h3><strong>Requisitos de la etiqueta de arco el\u00e9ctrico del NEC<\/strong><\/h3><p>El hecho de que la Excepci\u00f3n 2 establezca condiciones en las que ya no se pueda exigir informaci\u00f3n detallada en la etiqueta no significa que se haya eliminado la necesidad de incluir etiquetas. El NEC sigue teniendo sus requisitos.<\/p><p><em>110.16, Advertencia de peligro de arco el\u00e9ctrico: Los equipos el\u00e9ctricos, como tableros de distribuci\u00f3n, equipos de conmutaci\u00f3n, tableros de distribuci\u00f3n, paneles de control industrial y centros de control de motores que se encuentran en unidades que no sean de vivienda y que probablemente requieran examen, ajuste, servicio o mantenimiento mientras est\u00e9n energizados, deber\u00e1n estar marcados en el campo para advertir a las personas calificadas sobre los posibles peligros de arco el\u00e9ctrico.<\/em><\/p><h3><strong>\u00bfY ahora qu\u00e9?<\/strong><\/h3><p>\u00bfSe va a hacer mucho esfuerzo para que los estudios ya no incluyan informaci\u00f3n detallada en las etiquetas cuando se cumplan las condiciones de la Excepci\u00f3n 2? Es demasiado pronto para saberlo, pero independientemente de si se incluye o no la informaci\u00f3n detallada, hay una cosa que no cambiar\u00e1: el \u00e9nfasis en que los equipos se coloquen en condiciones de trabajo el\u00e9ctricamente seguras. Esperemos que las dos \u00faltimas palabras de la Excepci\u00f3n 2, \u201cmientras est\u00e9n bajo tensi\u00f3n\u201d, sean la verdadera excepci\u00f3n.<\/p><p>Nota: Aunque soy vicepresidente de IEEE 1584, presidente internacional de IEC TC78 y miembro del Comit\u00e9 Directivo de Investigaci\u00f3n Colaborativa sobre Arco El\u00e9ctrico IEEE\/NFPA, este art\u00edculo no debe considerarse una interpretaci\u00f3n directa o impl\u00edcita de NEC, la Asociaci\u00f3n Nacional de Protecci\u00f3n contra Incendios, IEEE o cualquier otra norma.<\/p><p>Basado en mi art\u00edculo publicado originalmente en la revista Electrical Contractor Magazine \u2013 noviembre de 2017<\/p><figure id=\"attachment_5006\" aria-describedby=\"caption-attachment-5006\" style=\"width: 216px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/brainfiller.com\/es\/videos\/\"><img decoding=\"async\" class=\"wp-image-5006\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/06\/2018-NFPA-70E-Training-4.jpg\" alt=\"Watch Jim's FREE 1 Hour 2018 NFPA 70E Update Video\" width=\"216\" height=\"162\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/06\/2018-NFPA-70E-Training-4.jpg 960w, https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/06\/2018-NFPA-70E-Training-4-600x450.jpg 600w, https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/06\/2018-NFPA-70E-Training-4-300x225.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/06\/2018-NFPA-70E-Training-4-768x576.jpg 768w\" sizes=\"(max-width: 216px) 100vw, 216px\" \/><\/a><figcaption id=\"caption-attachment-5006\" class=\"wp-caption-text\">V\u00eddeo gratuito de 1 hora Mira aqu\u00ed<\/figcaption><\/figure><p><strong><span style=\"color: #ff6600;\">\u00bfQuiere aprender m\u00e1s sobre mis clases de seguridad el\u00e9ctrica y la edici\u00f3n 2018 de NFPA 70E?<\/span><\/strong><\/p><p><span style=\"color: #ff6600;\"><strong><a href=\"https:\/\/brainfiller.com\/es\/electrical-safety\/\">Clases de seguridad el\u00e9ctrica<\/a><\/strong><\/span><\/p><p><span style=\"color: #ff6600;\"><a href=\"https:\/\/brainfiller.com\/es\/courses\/electrical-safety-and-nfpa-70e-2-day\/\"><strong>Clases programadas de NFPA 70E<\/strong><\/a><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-11635f1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"11635f1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5ee9b29\" data-id=\"5ee9b29\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1c11da8 elementor-widget elementor-widget-gallery\" data-id=\"1c11da8\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;lazyload&quot;:&quot;yes&quot;,&quot;gallery_layout&quot;:&quot;grid&quot;,&quot;columns&quot;:4,&quot;columns_tablet&quot;:2,&quot;columns_mobile&quot;:1,&quot;gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:10,&quot;sizes&quot;:[]},&quot;gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:10,&quot;sizes&quot;:[]},&quot;gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:10,&quot;sizes&quot;:[]},&quot;link_to&quot;:&quot;file&quot;,&quot;aspect_ratio&quot;:&quot;3:2&quot;,&quot;overlay_background&quot;:&quot;yes&quot;,&quot;content_hover_animation&quot;:&quot;fade-in&quot;}\" data-widget_type=\"gallery.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-gallery__container\">\n\t\t\t\t\t\t\t<a class=\"e-gallery-item elementor-gallery-item elementor-animated-content\" href=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/10\/ANSIZ535-Label-Simple-1-scaled.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"1c11da8\" data-elementor-lightbox-title=\"ANSIZ535 Label Simple\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzQ5NDcsInVybCI6Imh0dHBzOlwvXC9icmFpbmZpbGxlci5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcLzIwMjNcLzEwXC9BTlNJWjUzNS1MYWJlbC1TaW1wbGUtMS1zY2FsZWQuanBnIiwic2xpZGVzaG93IjoiMWMxMWRhOCJ9\">\n\t\t\t\t\t<div class=\"e-gallery-image elementor-gallery-item__image\" data-thumbnail=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/10\/ANSIZ535-Label-Simple-1-300x206.jpg\" data-width=\"300\" data-height=\"206\" aria-label=\"Requisitos de la calcoman\u00eda de arco el\u00e9ctrico\" role=\"img\" ><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-gallery-item__overlay\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<a class=\"e-gallery-item elementor-gallery-item elementor-animated-content\" href=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/10\/IMG_2076-scaled.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"1c11da8\" data-elementor-lightbox-title=\"IMG_2076\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzQ5NDksInVybCI6Imh0dHBzOlwvXC9icmFpbmZpbGxlci5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcLzIwMjNcLzEwXC9JTUdfMjA3Ni1zY2FsZWQuanBnIiwic2xpZGVzaG93IjoiMWMxMWRhOCJ9\">\n\t\t\t\t\t<div class=\"e-gallery-image elementor-gallery-item__image\" data-thumbnail=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/10\/IMG_2076-300x225.jpg\" data-width=\"300\" data-height=\"225\" aria-label=\"Etiquetas de arco el\u00e9ctrico NFPA 70E\" role=\"img\" ><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-gallery-item__overlay\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<a class=\"e-gallery-item elementor-gallery-item elementor-animated-content\" href=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/10\/IMG_7311-scaled.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"1c11da8\" data-elementor-lightbox-title=\"IMG_7311\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzQ5NTAsInVybCI6Imh0dHBzOlwvXC9icmFpbmZpbGxlci5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcLzIwMjNcLzEwXC9JTUdfNzMxMS1zY2FsZWQuanBnIiwic2xpZGVzaG93IjoiMWMxMWRhOCJ9\">\n\t\t\t\t\t<div class=\"e-gallery-image elementor-gallery-item__image\" data-thumbnail=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/10\/IMG_7311-300x200.jpg\" data-width=\"300\" data-height=\"200\" aria-label=\"Etiquetas: Uno de los requisitos de arco el\u00e9ctrico de la NFPA 70E\" role=\"img\" ><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-gallery-item__overlay\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<a class=\"e-gallery-item elementor-gallery-item elementor-animated-content\" href=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/06\/2024-NFPA-70E-scaled.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-slideshow=\"1c11da8\" data-elementor-lightbox-title=\"2024 NFPA 70E\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzMwMzQsInVybCI6Imh0dHBzOlwvXC9icmFpbmZpbGxlci5jb21cL3dwLWNvbnRlbnRcL3VwbG9hZHNcLzIwMjNcLzA2XC8yMDI0LU5GUEEtNzBFLXNjYWxlZC5qcGciLCJzbGlkZXNob3ciOiIxYzExZGE4In0%3D\">\n\t\t\t\t\t<div class=\"e-gallery-image elementor-gallery-item__image\" data-thumbnail=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2023\/06\/2024-NFPA-70E-232x300.jpg\" data-width=\"232\" data-height=\"300\" aria-label=\"Requisitos de la etiqueta de riesgo de arco el\u00e9ctrico de la NFPA 70E\" role=\"img\" ><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-gallery-item__overlay\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>New Exception 130.5(H) Exception No. 2 &#8211; Arc Flash Hazard Label Information May Not Be Required. It is amazing how the requirements for arc flash labeling have evolved with each new edition of NFPA 70E. Known as Arc Flash Warning&#8230;<\/p>","protected":false},"author":2,"featured_media":12742,"comment_status":"open","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":""},"categories":[9,410,406,404,403,412,413,407,419,408],"tags":[],"class_list":["post-5269","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arc-flash-electrical-safety","category-arc-flash-labeling-and-compliance-requirements","category-arc-flash-safety-and-hazard-analysis","category-electrical-power-system-design-and-analysis","category-electrical-safety-codes-and-standards","category-electrical-safety-training-and-culture","category-electrical-testing-and-maintenance-diagnostics","category-emerging-electrical-safety-technologies-and-trends","category-nfpa-70e","category-short-circuit-analysis-and-fault-current-calculations"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Arc Flash Labels \u2013 Information No Longer Required (maybe) - Arc Flash &amp; Electrical Power Training | Brainfiller<\/title>\n<meta name=\"description\" content=\"New Exception 130.5(H) Exception No. 2 - Arc Flash Hazard Label Information May Not Be Required. It is amazing how the requirements for arc flash labeling have evolved with each new edition of NFPA 70E. Known as Arc Flash Warning...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Arc Flash Labels \u2013 Information No Longer Required (maybe) - Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"og:description\" content=\"New Exception 130.5(H) Exception No. 2 - Arc Flash Hazard Label Information May Not Be Required. It is amazing how the requirements for arc flash labeling have evolved with each new edition of NFPA 70E. Known as Arc Flash Warning...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/\" \/>\n<meta property=\"og:site_name\" content=\"Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400\" \/>\n<meta property=\"article:author\" content=\"Jim Phillips \/ Brainfiller.com\" \/>\n<meta property=\"article:published_time\" content=\"2018-01-15T19:08:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-21T21:24:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2020\/04\/warning.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"320\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Jim Phillips\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:site\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jim Phillips\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/\"},\"author\":{\"name\":\"Jim Phillips\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/03247835e81df659321c6b756e0389e5\"},\"headline\":\"Arc Flash Labels \u2013 Information No Longer Required (maybe)\",\"datePublished\":\"2018-01-15T19:08:17+00:00\",\"dateModified\":\"2025-11-21T21:24:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/\"},\"wordCount\":1143,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/warning.jpg\",\"articleSection\":[\"Arc Flash and Electrical Safety\",\"Arc Flash Labeling and Compliance Requirements\",\"Arc Flash Safety and Hazard Analysis\",\"Electrical Power System Design and Analysis\",\"Electrical Safety Codes and Standards\",\"Electrical Safety Training and Culture\",\"Electrical Testing and Maintenance Diagnostics\",\"Emerging Electrical Safety Technologies and Trends\",\"NFPA 70E\",\"Short Circuit Analysis and Fault Current Calculations\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/\",\"name\":\"Arc Flash Labels \u2013 Information No Longer Required (maybe) - Arc Flash &amp; Electrical Power Training | Brainfiller\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/warning.jpg\",\"datePublished\":\"2018-01-15T19:08:17+00:00\",\"dateModified\":\"2025-11-21T21:24:51+00:00\",\"description\":\"New Exception 130.5(H) Exception No. 2 - Arc Flash Hazard Label Information May Not Be Required. It is amazing how the requirements for arc flash labeling have evolved with each new edition of NFPA 70E. Known as Arc Flash Warning...\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/warning.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/warning.jpg\",\"width\":320,\"height\":300,\"caption\":\"Arc Flash Labeling Requirments\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/arc-flash-electrical-safety\\\/arc-flash-labels-exception2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/brainfiller.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Arc Flash Labels \u2013 Information No Longer Required (maybe)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"name\":\"Arc Flash & Electrical Power Training | Brainfiller\",\"description\":\"Arc Flash &amp; Electrical Power Training by Jim Phillips\",\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/brainfiller.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\",\"name\":\"Brainfiller.com\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"width\":128,\"height\":118,\"caption\":\"Brainfiller.com\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/pages\\\/Brainfiller\\\/121692927901400\",\"https:\\\/\\\/x.com\\\/brainfiller\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/brainfiller\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/BrainfillerTV\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/03247835e81df659321c6b756e0389e5\",\"name\":\"Jim Phillips\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g\",\"caption\":\"Jim Phillips\"},\"description\":\"It's an epic saga....\",\"sameAs\":[\"Jim Phillips \\\/ Brainfiller.com\",\"https:\\\/\\\/x.com\\\/brainfiller\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Arc Flash Labels \u2013 Information No Longer Required (maybe) - Arc Flash &amp; Electrical Power Training | Brainfiller","description":"New Exception 130.5(H) Exception No. 2 - Arc Flash Hazard Label Information May Not Be Required. It is amazing how the requirements for arc flash labeling have evolved with each new edition of NFPA 70E. Known as Arc Flash Warning...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/","og_locale":"es_MX","og_type":"article","og_title":"Arc Flash Labels \u2013 Information No Longer Required (maybe) - Arc Flash &amp; Electrical Power Training | Brainfiller","og_description":"New Exception 130.5(H) Exception No. 2 - Arc Flash Hazard Label Information May Not Be Required. It is amazing how the requirements for arc flash labeling have evolved with each new edition of NFPA 70E. Known as Arc Flash Warning...","og_url":"https:\/\/brainfiller.com\/es\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/","og_site_name":"Arc Flash &amp; Electrical Power Training | Brainfiller","article_publisher":"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","article_author":"Jim Phillips \/ Brainfiller.com","article_published_time":"2018-01-15T19:08:17+00:00","article_modified_time":"2025-11-21T21:24:51+00:00","og_image":[{"width":320,"height":300,"url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2020\/04\/warning.jpg","type":"image\/jpeg"}],"author":"Jim Phillips","twitter_card":"summary_large_image","twitter_creator":"@brainfiller","twitter_site":"@brainfiller","twitter_misc":{"Escrito por":"Jim Phillips","Tiempo de lectura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#article","isPartOf":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/"},"author":{"name":"Jim Phillips","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/03247835e81df659321c6b756e0389e5"},"headline":"Arc Flash Labels \u2013 Information No Longer Required (maybe)","datePublished":"2018-01-15T19:08:17+00:00","dateModified":"2025-11-21T21:24:51+00:00","mainEntityOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/"},"wordCount":1143,"commentCount":0,"publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2020\/04\/warning.jpg","articleSection":["Arc Flash and Electrical Safety","Arc Flash Labeling and Compliance Requirements","Arc Flash Safety and Hazard Analysis","Electrical Power System Design and Analysis","Electrical Safety Codes and Standards","Electrical Safety Training and Culture","Electrical Testing and Maintenance Diagnostics","Emerging Electrical Safety Technologies and Trends","NFPA 70E","Short Circuit Analysis and Fault Current Calculations"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/","url":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/","name":"Arc Flash Labels \u2013 Information No Longer Required (maybe) - Arc Flash &amp; Electrical Power Training | Brainfiller","isPartOf":{"@id":"https:\/\/brainfiller.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#primaryimage"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2020\/04\/warning.jpg","datePublished":"2018-01-15T19:08:17+00:00","dateModified":"2025-11-21T21:24:51+00:00","description":"New Exception 130.5(H) Exception No. 2 - Arc Flash Hazard Label Information May Not Be Required. It is amazing how the requirements for arc flash labeling have evolved with each new edition of NFPA 70E. Known as Arc Flash Warning...","breadcrumb":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#primaryimage","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2020\/04\/warning.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2020\/04\/warning.jpg","width":320,"height":300,"caption":"Arc Flash Labeling Requirments"},{"@type":"BreadcrumbList","@id":"https:\/\/brainfiller.com\/brainfiller-library\/arc-flash-electrical-safety\/arc-flash-labels-exception2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/brainfiller.com\/"},{"@type":"ListItem","position":2,"name":"Arc Flash Labels \u2013 Information No Longer Required (maybe)"}]},{"@type":"WebSite","@id":"https:\/\/brainfiller.com\/#website","url":"https:\/\/brainfiller.com\/","name":"Arc Flash & Electrical Power Training | Brainfiller","description":"Arc Flash &amp; Electrical Power Training by Jim Phillips","publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/brainfiller.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/brainfiller.com\/#organization","name":"Rellenador de cerebros.com","url":"https:\/\/brainfiller.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","width":128,"height":118,"caption":"Brainfiller.com"},"image":{"@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","https:\/\/x.com\/brainfiller","https:\/\/www.linkedin.com\/in\/brainfiller","https:\/\/www.youtube.com\/user\/BrainfillerTV"]},{"@type":"Person","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/03247835e81df659321c6b756e0389e5","name":"Jim Phillips","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/258153a7b4455d57ac848a4f6ee7f9267354ff8620a5dbe6147c911dfb739491?s=96&d=mm&r=g","caption":"Jim Phillips"},"description":"It's an epic saga....","sameAs":["Jim Phillips \/ Brainfiller.com","https:\/\/x.com\/brainfiller"]}]}},"ticketed":false,"_links":{"self":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/5269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/comments?post=5269"}],"version-history":[{"count":0,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/5269\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media\/12742"}],"wp:attachment":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media?parent=5269"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/categories?post=5269"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/tags?post=5269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}