{"id":75,"date":"2012-05-29T17:26:42","date_gmt":"2012-05-30T00:26:42","guid":{"rendered":"https:\/\/brainfiller.com\/staging\/?p=75"},"modified":"2025-11-21T14:24:52","modified_gmt":"2025-11-21T21:24:52","slug":"working-distance-mistakes-in-an-arc-flash-study","status":"publish","type":"post","link":"https:\/\/brainfiller.com\/es\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/","title":{"rendered":"Errores de distancia de trabajo en un estudio de arco el\u00e9ctrico"},"content":{"rendered":"<p><a href=\"https:\/\/brainfiller.com\/es\/producto\/free-arc-flash-hazard-calculation-guide\/\"><img decoding=\"async\" class=\"alignright wp-image-3702 size-thumbnail\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-150x150.jpg\" alt=\"Download FREE Arc Flash Calculations\" width=\"150\" height=\"150\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-150x150.jpg 150w, https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-300x300.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-100x100.jpg 100w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/a><\/p>\n<p>El t\u00e9rmino \u201cdistancia de trabajo\u201d aparece 20 veces en la edici\u00f3n 2012 de la norma NFPA 70E, la norma para la seguridad el\u00e9ctrica en el lugar de trabajo. Aparece 12 veces m\u00e1s en los anexos. La distancia de trabajo es un componente importante del an\u00e1lisis de peligros de arco el\u00e9ctrico y se incluye con frecuencia en las etiquetas de advertencia de arco el\u00e9ctrico y en el informe de arco el\u00e9ctrico.<\/p>\n<p>La IEEE 1584\u2014Gu\u00eda IEEE para realizar c\u00e1lculos de riesgo de arco el\u00e9ctrico 2002 define la distancia de trabajo como \u201cla dimensi\u00f3n entre el posible punto de arco y la cabeza y el cuerpo del trabajador posicionado en el lugar para realizar la tarea asignada\u201d.<\/p>\n<p>Cuando se calcula la energ\u00eda incidente como parte de un an\u00e1lisis, corresponde a una distancia espec\u00edfica de la posible fuente de arco el\u00e9ctrico, lo que hace que la distancia de trabajo sea un dato muy importante. Si una persona se encuentra a una distancia menor que la de trabajo, la energ\u00eda incidente aumenta dr\u00e1sticamente.<\/p>\n<p><a href=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2012\/05\/Working-Distance-Table.jpg\"><img decoding=\"async\" class=\"wp-image-1390 alignleft\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2012\/05\/Working-Distance-Table.jpg\" alt=\"Working Distance Table\" width=\"167\" height=\"162\" \/><\/a><\/p>\n<p>La tabla ilustra c\u00f3mo var\u00eda la energ\u00eda incidente con la distancia. Los c\u00e1lculos se realizaron para distancias que van desde 6 a 36 pulgadas para un panel de 480 voltios. Seg\u00fan la distancia que se utilice, la energ\u00eda incidente var\u00eda de 2,6 calor\u00edas por cent\u00edmetro cuadrado (cal\/cm2) a 48,5 cal\/cm2. Si no se incluye la distancia de trabajo, un trabajador no sabr\u00eda que 2,6 cal\/cm2 se basa en estar ubicado a una distancia m\u00ednima de 36 pulgadas.<\/p>\n<h2><span style=\"color: #ff6600;\"><strong>Cinco errores comunes (y peligrosos) en la distancia de trabajo<\/strong><\/span><\/h2>\n<p>Aunque la distancia de trabajo parece ser un concepto simple, no siempre se tiene debidamente en cuenta cuando se realizan trabajos con corriente el\u00e9ctrica. A continuaci\u00f3n, se enumeran cinco errores comunes:<\/p>\n<p><strong><span style=\"color: #ff6600;\">1) Trabajar demasiado cerca<\/span><\/strong>\u2014Aunque la distancia de trabajo puede estar indicada en la etiqueta de protecci\u00f3n contra arcos el\u00e9ctricos, a veces existe una tendencia a acercarse por diversos motivos. Esto podr\u00eda significar un problema en caso de un arco el\u00e9ctrico, ya que la energ\u00eda incidente ser\u00eda mayor. La capacitaci\u00f3n en seguridad el\u00e9ctrica y la instrucci\u00f3n del trabajo siempre deben enfatizar la importancia de mantener una distancia de trabajo adecuada e incluir un an\u00e1lisis de lo que podr\u00eda suceder si se reduce esta distancia.<\/p>\n<p><strong><span style=\"color: #ff6600;\">2) Partes del cuerpo m\u00e1s cercanas que la distancia de trabajo<\/span><\/strong>\u2014Incluso si se mantiene la distancia de trabajo correcta, es posible que otras partes del cuerpo, como las manos y los brazos, est\u00e9n m\u00e1s cerca de la fuente del arco el\u00e9ctrico. La norma NFPA 70E exige que se utilice protecci\u00f3n adicional para cualquier parte del cuerpo que est\u00e9 m\u00e1s cerca que la distancia utilizada para determinar la energ\u00eda incidente.<\/p>\n<p><strong><span style=\"color: #ff6600;\">3) Datos de entrada incorrectos<\/span><\/strong>\u2014Al realizar estudios de arco el\u00e9ctrico con software disponible comercialmente, se debe tener cuidado de seleccionar una distancia de trabajo adecuada. La norma IEEE 1584 sugiere una distancia de trabajo que va de 18 a 36 pulgadas, seg\u00fan el tipo de equipo y el nivel de voltaje. Muchas veces, he revisado estudios de arco el\u00e9ctrico y descubr\u00ed que la distancia seleccionada no es la que la IEEE sugiere para el equipo. Si se utiliza una distancia de trabajo mayor a la normal, puede dar una falsa sensaci\u00f3n de seguridad al sugerir que la energ\u00eda incidente es mucho menor de lo que podr\u00eda ser.<\/p>\n<p><strong><span style=\"color: #ff6600;\">4) Piezas energizadas inesperadas en el frente<\/span><\/strong>\u2014La distancia de trabajo parece ser un concepto simple hasta que...<br \/>\nIntente determinar la ubicaci\u00f3n de la posible fuente del arco. \u00bfEst\u00e1 energizada la barra del equipo?<br \/>\n\u00bfEst\u00e1n ubicados hacia la parte trasera del gabinete, como suele ser el caso? \u00bfO tambi\u00e9n hay conductores energizados ubicados m\u00e1s cerca del frente? \u00bfC\u00f3mo lo sabr\u00eda antes de abrir la puerta del gabinete? La distancia de trabajo generalmente supone que los conductores energizados est\u00e1n ubicados cerca de la parte trasera del equipo, pero eso puede no ser siempre cierto.<\/p>\n<p><strong><span style=\"color: #ff6600;\">5) Equipo accesible desde atr\u00e1s<\/span><\/strong>\u2014Los equipos el\u00e9ctricos a los que se puede acceder desde atr\u00e1s pueden dar lugar a una gran sorpresa al abrirlos. En lugar de que el bus energizado est\u00e9 ubicado en la parte trasera, ahora usted est\u00e1 en la parte trasera y la distancia de trabajo puede ser muy corta. Cualquier trabajo en tensi\u00f3n que se realice en la parte trasera debe tener en cuenta esta distancia de trabajo muy reducida. Normalmente, esta situaci\u00f3n requiere un segundo conjunto de c\u00e1lculos y etiquetas en funci\u00f3n de la corta distancia de trabajo.<\/p>\n<h2><span style=\"color: #ff6600;\"><strong>\u00bfDemasiado cerca?<\/strong><\/span><\/h2>\n<p>La distancia es fundamental cuando se trata de un arco el\u00e9ctrico. Los trabajadores nunca deben estar a una distancia inferior a la distancia de trabajo asociada con la energ\u00eda incidente para la que est\u00e1n protegidos. Si se hace necesaria una distancia de trabajo diferente, se requerir\u00e1n nuevos c\u00e1lculos para determinar el aumento de la energ\u00eda incidente y los requisitos para una posible mayor protecci\u00f3n. Acercarse demasiado podr\u00eda ser catastr\u00f3fico.<\/p>\n<p><strong>Por <a href=\"https:\/\/brainfiller.com\/es\/jim-phillips\/about-jim-phillips\/\">Jim Phillips<\/a> | Brainfiller, Inc. | Foro ArcFlash.com<\/strong><br \/>\n<strong>Publicado originalmente: marzo de 2012 |\u00a0<a href=\"http:\/\/www.ecmag.com\/\">Revista del contratista el\u00e9ctrico<\/a>\u00a0<\/strong><\/p>\n<hr \/>\n<p><em><strong><a href=\"https:\/\/www.youtube.com\/watch?v=FkLDfyr8s2U&amp;feature=youtu.be\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignright size-medium wp-image-5236\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Screen-Shot-2018-01-10-at-12.22.59-PM-300x226.png\" alt=\"NFPA70E 2018 Update video by Jim Phillips\" width=\"300\" height=\"226\" \/><\/a>Acerca de Jim Phillips, PE:<\/strong><\/em><em>\u00a0<\/em><em>Programas de capacitaci\u00f3n sobre energ\u00eda el\u00e9ctrica y arco el\u00e9ctrico: durante m\u00e1s de 30 a\u00f1os, Jim Phillips ha ayudado a decenas de miles de personas en todo el mundo a comprender el dise\u00f1o, el an\u00e1lisis, el arco el\u00e9ctrico y la seguridad el\u00e9ctrica de los sistemas de energ\u00eda el\u00e9ctrica.<\/em> <em>Jim es vicepresidente de IEEE 1584 y presidente internacional de IEC TC78 Live Working. Se ha ganado la reputaci\u00f3n de ser uno de los mejores capacitadores en la industria de la energ\u00eda el\u00e9ctrica.<\/em><strong><em>,<\/em><\/strong><strong><em>\u00a0<\/em><\/strong><a href=\"http:\/\/www.staging28.brainfiller.com\/scheduled-events\/\"><em><strong>M\u00e1s informaci\u00f3n<\/strong><\/em><\/a><em>.<\/em><\/p>\n<p><a href=\"https:\/\/brainfiller.com\/es\/courses\/how-to-perform-an-arc-flash-hazard-calculation-study-2-days\/\"><strong>haga clic aqu\u00ed<\/strong><\/a>\u00a0Para el futuro\u00a0<strong>Capacitaci\u00f3n sobre seguridad frente a arcos el\u00e9ctricos<\/strong><\/p>\n<p><a href=\"https:\/\/brainfiller.com\/es\/scheduled-events\/\"><strong>haga clic aqu\u00ed<\/strong><\/a> <strong>Para todos los programados<\/strong><strong> Capacitaci\u00f3n en seguridad el\u00e9ctrica<\/strong><\/p>\n<p><a href=\"https:\/\/brainfiller.com\/es\/on-site-training\/\"><strong>haga clic aqu\u00ed<\/strong><\/a> <strong>Para solicitar una <\/strong><strong>Capacitaci\u00f3n en el sitio<\/strong><\/p>\n<p><a href=\"https:\/\/visitor.r20.constantcontact.com\/manage\/optin?v=001EYE_9pNc5E2BUxrXsTBIKu4Lh1YODid1\"><strong>Inscribirse<\/strong><em>\u00a0<\/em><\/a><em>para mi publicaci\u00f3n mensual \u201cGrey Matter\u201d que contiene noticias sobre nuevos est\u00e1ndares, conferencias, art\u00edculos t\u00e9cnicos, noticias de ingenier\u00eda el\u00e9ctrica y mucho m\u00e1s.<\/em><\/p>","protected":false},"excerpt":{"rendered":"<p>The term \u201cworking distance\u201d appears 20 times in the 2012 Edition of NFPA 70E, the Standard for Electrical\u00a0Safety in the Workplace. It appears 12 more times in the annexes. The [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":46440,"comment_status":"open","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"Tribe__Tickets_Plus__Commerce__WooCommerce__Main","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":""},"categories":[9,7,419],"tags":[44,11,47,49],"class_list":["post-75","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arc-flash-electrical-safety","category-brainfiller-library","category-nfpa-70e","tag-arc-flash-study","tag-ieee-1584","tag-nfpa-70e","tag-working-distance"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Working Distance Mistakes in an Arc Flash Study<\/title>\n<meta name=\"description\" content=\"Working Distance: \u201cthe dimension between the possible arc point and the head and body of the worker positioned in place to perform the assigned task.\u201d\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Working Distance Mistakes in an Arc Flash Study\" \/>\n<meta property=\"og:description\" content=\"Working Distance: \u201cthe dimension between the possible arc point and the head and body of the worker positioned in place to perform the assigned task.\u201d\" \/>\n<meta property=\"og:url\" content=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/\" \/>\n<meta property=\"og:site_name\" content=\"Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400\" \/>\n<meta property=\"article:published_time\" content=\"2012-05-30T00:26:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-21T21:24:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"528\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Jim Phillips\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:site\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jim Phillips\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/\"},\"author\":{\"name\":\"Jim Phillips\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/4e1b5b26ff96ad8021b5886cc43de1e8\"},\"headline\":\"Working Distance Mistakes in an Arc Flash Study\",\"datePublished\":\"2012-05-30T00:26:42+00:00\",\"dateModified\":\"2025-11-21T21:24:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/\"},\"wordCount\":836,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"keywords\":[\"arc flash study\",\"IEEE 1584\",\"nfpa 70e\",\"working distance\"],\"articleSection\":[\"Arc Flash and Electrical Safety\",\"Brainfiller Library\",\"NFPA 70E\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/\",\"name\":\"Working Distance Mistakes in an Arc Flash Study\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"datePublished\":\"2012-05-30T00:26:42+00:00\",\"dateModified\":\"2025-11-21T21:24:52+00:00\",\"description\":\"Working Distance: \u201cthe dimension between the possible arc point and the head and body of the worker positioned in place to perform the assigned task.\u201d\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#primaryimage\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"width\":800,\"height\":528},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/working-distance-mistakes-in-an-arc-flash-study\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/brainfiller.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Working Distance Mistakes in an Arc Flash Study\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"name\":\"Arc Flash & Electrical Power Training | Brainfiller\",\"description\":\"Arc Flash &amp; Electrical Power Training by Jim Phillips\",\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/brainfiller.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\",\"name\":\"Brainfiller.com\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"width\":128,\"height\":118,\"caption\":\"Brainfiller.com\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/pages\\\/Brainfiller\\\/121692927901400\",\"https:\\\/\\\/x.com\\\/brainfiller\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/brainfiller\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/BrainfillerTV\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/4e1b5b26ff96ad8021b5886cc43de1e8\",\"name\":\"Jim Phillips\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g\",\"caption\":\"Jim Phillips\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Errores de distancia de trabajo en un estudio de arco el\u00e9ctrico","description":"Working Distance: \u201cthe dimension between the possible arc point and the head and body of the worker positioned in place to perform the assigned task.\u201d","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/brainfiller.com\/es\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/","og_locale":"es_MX","og_type":"article","og_title":"Working Distance Mistakes in an Arc Flash Study","og_description":"Working Distance: \u201cthe dimension between the possible arc point and the head and body of the worker positioned in place to perform the assigned task.\u201d","og_url":"https:\/\/brainfiller.com\/es\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/","og_site_name":"Arc Flash &amp; Electrical Power Training | Brainfiller","article_publisher":"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","article_published_time":"2012-05-30T00:26:42+00:00","article_modified_time":"2025-11-21T21:24:52+00:00","og_image":[{"width":800,"height":528,"url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","type":"image\/jpeg"}],"author":"Jim Phillips","twitter_card":"summary_large_image","twitter_creator":"@brainfiller","twitter_site":"@brainfiller","twitter_misc":{"Escrito por":"Jim Phillips","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#article","isPartOf":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/"},"author":{"name":"Jim Phillips","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/4e1b5b26ff96ad8021b5886cc43de1e8"},"headline":"Working Distance Mistakes in an Arc Flash Study","datePublished":"2012-05-30T00:26:42+00:00","dateModified":"2025-11-21T21:24:52+00:00","mainEntityOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/"},"wordCount":836,"commentCount":0,"publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","keywords":["arc flash study","IEEE 1584","nfpa 70e","working distance"],"articleSection":["Arc Flash and Electrical Safety","Brainfiller Library","NFPA 70E"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/","url":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/","name":"Errores de distancia de trabajo en un estudio de arco el\u00e9ctrico","isPartOf":{"@id":"https:\/\/brainfiller.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#primaryimage"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","datePublished":"2012-05-30T00:26:42+00:00","dateModified":"2025-11-21T21:24:52+00:00","description":"Working Distance: \u201cthe dimension between the possible arc point and the head and body of the worker positioned in place to perform the assigned task.\u201d","breadcrumb":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#primaryimage","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","width":800,"height":528},{"@type":"BreadcrumbList","@id":"https:\/\/brainfiller.com\/brainfiller-library\/working-distance-mistakes-in-an-arc-flash-study\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/brainfiller.com\/"},{"@type":"ListItem","position":2,"name":"Working Distance Mistakes in an Arc Flash Study"}]},{"@type":"WebSite","@id":"https:\/\/brainfiller.com\/#website","url":"https:\/\/brainfiller.com\/","name":"Arc Flash & Electrical Power Training | Brainfiller","description":"Arc Flash &amp; Electrical Power Training by Jim Phillips","publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/brainfiller.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/brainfiller.com\/#organization","name":"Rellenador de cerebros.com","url":"https:\/\/brainfiller.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","width":128,"height":118,"caption":"Brainfiller.com"},"image":{"@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","https:\/\/x.com\/brainfiller","https:\/\/www.linkedin.com\/in\/brainfiller","https:\/\/www.youtube.com\/user\/BrainfillerTV"]},{"@type":"Person","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/4e1b5b26ff96ad8021b5886cc43de1e8","name":"Jim Phillips","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g","caption":"Jim Phillips"}}]}},"ticketed":false,"_links":{"self":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/75","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/comments?post=75"}],"version-history":[{"count":0,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/75\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media\/46440"}],"wp:attachment":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media?parent=75"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/categories?post=75"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/tags?post=75"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}