{"id":96,"date":"2010-12-31T17:36:04","date_gmt":"2011-01-01T00:36:04","guid":{"rendered":"https:\/\/brainfiller.com\/staging\/?p=96"},"modified":"2025-11-21T14:24:53","modified_gmt":"2025-11-21T21:24:53","slug":"ieee-1584-125-kva-transformer-less-than-240-volts-exception","status":"publish","type":"post","link":"https:\/\/brainfiller.com\/es\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/","title":{"rendered":"IEEE 1584 \u2013 Transformador de 125 kVA \/ Excepci\u00f3n de menos de 240 voltios"},"content":{"rendered":"<figure id=\"attachment_3702\" aria-describedby=\"caption-attachment-3702\" style=\"width: 150px\" class=\"wp-caption alignright\"><a href=\"https:\/\/brainfiller.com\/es\/producto\/free-arc-flash-hazard-calculation-guide\/\"><img decoding=\"async\" class=\"size-thumbnail wp-image-3702\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-150x150.jpg 150w, https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-300x300.jpg 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2017\/02\/arc-100x100.jpg 100w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/a><figcaption id=\"caption-attachment-3702\" class=\"wp-caption-text\">Descargue c\u00e1lculos de arco el\u00e9ctrico GRATIS<\/figcaption><\/figure>\n<p>Una frase de la norma IEEE 1584, Gu\u00eda IEEE para realizar c\u00e1lculos de riesgo de arco el\u00e9ctrico, con frecuencia deja a la gente perpleja: No es necesario considerar los equipos por debajo de 240 V a menos que involucren al menos un transformador de baja impedancia de 125 kVA o m\u00e1s en su suministro de energ\u00eda inmediata. \u00bfQu\u00e9 significa esta frase? \u00bfQu\u00e9 tienen de importante los 240 voltios y los 125 kilovoltamperios?<\/p>\n<p><strong>Descargar: \u00a0<span style=\"color: #ff6600;\"><a style=\"color: #ff6600;\" href=\"http:\/\/EC 2010-09 125 kVA Exception Jim Phillips\">Excepci\u00f3n de 125 kVA\/240 voltios<\/a><\/span><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong><em>Acerca de Jim Phillips:<\/em><\/strong><em> Programas de capacitaci\u00f3n sobre energ\u00eda el\u00e9ctrica y arco el\u00e9ctrico: durante m\u00e1s de 30 a\u00f1os, Jim Phillips ha ayudado a decenas de miles de personas en todo el mundo a comprender el dise\u00f1o, el an\u00e1lisis, el arco el\u00e9ctrico y la seguridad el\u00e9ctrica de los sistemas de energ\u00eda el\u00e9ctrica.<\/em><\/p>\n<p><em><a href=\"https:\/\/youtu.be\/FkLDfyr8s2U\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignright wp-image-5236 size-medium\" src=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Screen-Shot-2018-01-10-at-12.22.59-PM-300x226.png\" sizes=\"(max-width: 300px) 100vw, 300px\" srcset=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Screen-Shot-2018-01-10-at-12.22.59-PM-300x226.png 300w, https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Screen-Shot-2018-01-10-at-12.22.59-PM-768x577.png 768w, https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Screen-Shot-2018-01-10-at-12.22.59-PM-1024x770.png 1024w, https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Screen-Shot-2018-01-10-at-12.22.59-PM.png 1032w\" alt=\"NFPA70E 2018 Update video by Jim Phillips\" width=\"300\" height=\"226\" \/><\/a>Jim es vicepresidente de IEEE 1584, presidente internacional de IEC TC78 Live Working y miembro del comit\u00e9 directivo del proyecto de investigaci\u00f3n colaborativa sobre arcos el\u00e9ctricos IEEE\/NFPA. Se ha ganado la reputaci\u00f3n de ser uno de los mejores formadores en la industria de la energ\u00eda el\u00e9ctrica.<strong>\u00a0\u00a0<\/strong><\/em><a href=\"http:\/\/www.staging28.brainfiller.com\/scheduled-events\/\"><strong><em>M\u00e1s informaci\u00f3n<\/em><\/strong><\/a><\/p>\n<p><strong><em><a href=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Screen-Shot-2018-01-10-at-12.08.06-PM.png\"><br \/>\n<\/a>Clases de capacitaci\u00f3n sobre arco el\u00e9ctrico y energ\u00eda el\u00e9ctrica<\/em><\/strong><em>\u00a0Por Jim Phillips\u00a0<\/em><a href=\"https:\/\/brainfiller.com\/es\/scheduled-events\/\"><strong><em>Haga clic aqu\u00ed<\/em><\/strong><\/a><\/p>\n<p><em><strong>Productos de capacitaci\u00f3n sobre arco el\u00e9ctrico y energ\u00eda el\u00e9ctrica<\/strong><\/em>\u00a0<em>Por Jim Phillips<\/em> <em><strong><a href=\"https:\/\/brainfiller.com\/es\/products\/\">Haga clic aqu\u00ed<\/a><\/strong><\/em><\/p>\n<p><a href=\"https:\/\/visitor.r20.constantcontact.com\/manage\/optin?v=001EYE_9pNc5E2BUxrXsTBIKpYeS4zKahN7LCWPUtPREhpLp0iqO5TmWGyOrU9UbuFWg0P9-J5pOAhY3jB4IDtoce2Z_fAebaYxYyKwewPByasnhZiSSWwGv154mJmimFJ5VkDQqxARpaQPjgB9EigIyern9MG9BkDhcQ8C29E5zBlwiDX7Zu5A8eaktisDxC8gBXqjn6B0UByMcUcVptgsapvCLAUqhuVrMVdwdiWgeIY_mxa8wMSLVTgCyZlqCNWpKsRAh6jJt20-4GbFTuBxfP0SBXjpZ4lOHilb6aVO6pb5Jrgljnq-D66dJisDOFWME1x8dndE4m1uevjZ_PQnvQ%3D%3D\"><strong><em>Inscribirse<\/em><\/strong><\/a><em> para mi publicaci\u00f3n mensual \u201cGrey Matter\u201d que contiene noticias sobre nuevos est\u00e1ndares, conferencias, art\u00edculos t\u00e9cnicos, noticias de ingenier\u00eda el\u00e9ctrica y mucho m\u00e1s. <\/em><a href=\"https:\/\/visitor.r20.constantcontact.com\/d.jsp?llr=v9okbfcab&amp;p=oi&amp;m=1101828275029&amp;sit=dl4faovcb&amp;f=08e41dea-9c84-4b90-8da7-9b4eb49b33de\"><strong><em>Haga clic aqu\u00ed<\/em><\/strong><\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>One sentence in the IEEE 1584 Standard, IEEE Guide for Performing Arc-Flash Hazard Calculations, frequently has people scratching their heads: Equipment below 240V need not be considered unless it involves [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":46440,"comment_status":"open","ping_status":"closed","sticky":false,"template":"elementor_theme","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":""},"categories":[9,7,35,419],"tags":[53,8,54,44,11,13],"class_list":["post-96","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-arc-flash-electrical-safety","category-brainfiller-library","category-electrical-power-systems-brainfiller-library","category-nfpa-70e","tag-125-kva-exception","tag-arc-flash","tag-arc-flash-calculations","tag-arc-flash-study","tag-ieee-1584","tag-jim-phillips"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>IEEE 1584 125 kVA Transformer Less than 240 Volts Exception<\/title>\n<meta name=\"description\" content=\"IEEE 1584 Standard, IEEE Guide for Performing Arc-Flash Hazard Calculations, has an exception for circuits fed by 125 kVA transformers less than 240 volts.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IEEE 1584 125 kVA Transformer Less than 240 Volts Exception\" \/>\n<meta property=\"og:description\" content=\"IEEE 1584 Standard, IEEE Guide for Performing Arc-Flash Hazard Calculations, has an exception for circuits fed by 125 kVA transformers less than 240 volts.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/brainfiller.com\/es\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/\" \/>\n<meta property=\"og:site_name\" content=\"Arc Flash &amp; Electrical Power Training | Brainfiller\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400\" \/>\n<meta property=\"article:published_time\" content=\"2011-01-01T00:36:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-21T21:24:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"528\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Jim Phillips\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:site\" content=\"@brainfiller\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jim Phillips\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/\"},\"author\":{\"name\":\"Jim Phillips\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/4e1b5b26ff96ad8021b5886cc43de1e8\"},\"headline\":\"IEEE 1584 &#8211; 125 kVA Transformer \\\/ Less than 240 Volts Exception\",\"datePublished\":\"2011-01-01T00:36:04+00:00\",\"dateModified\":\"2025-11-21T21:24:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/\"},\"wordCount\":209,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"keywords\":[\"125 kVA exception\",\"arc flash\",\"arc flash calculations\",\"arc flash study\",\"IEEE 1584\",\"jim phillips\"],\"articleSection\":[\"Arc Flash and Electrical Safety\",\"Brainfiller Library\",\"Electrical Power Systems\",\"NFPA 70E\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/\",\"name\":\"IEEE 1584 125 kVA Transformer Less than 240 Volts Exception\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"datePublished\":\"2011-01-01T00:36:04+00:00\",\"dateModified\":\"2025-11-21T21:24:53+00:00\",\"description\":\"IEEE 1584 Standard, IEEE Guide for Performing Arc-Flash Hazard Calculations, has an exception for circuits fed by 125 kVA transformers less than 240 volts.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#primaryimage\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/brainfiller-brain-800x528-1.jpg\",\"width\":800,\"height\":528},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/brainfiller-library\\\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/brainfiller.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IEEE 1584 &#8211; 125 kVA Transformer \\\/ Less than 240 Volts Exception\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#website\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"name\":\"Arc Flash & Electrical Power Training | Brainfiller\",\"description\":\"Arc Flash &amp; Electrical Power Training by Jim Phillips\",\"publisher\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/brainfiller.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#organization\",\"name\":\"Brainfiller.com\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"contentUrl\":\"https:\\\/\\\/brainfiller.com\\\/wp-content\\\/uploads\\\/2015\\\/05\\\/Brain-Logo.jpg\",\"width\":128,\"height\":118,\"caption\":\"Brainfiller.com\"},\"image\":{\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/pages\\\/Brainfiller\\\/121692927901400\",\"https:\\\/\\\/x.com\\\/brainfiller\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/brainfiller\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/BrainfillerTV\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/brainfiller.com\\\/#\\\/schema\\\/person\\\/4e1b5b26ff96ad8021b5886cc43de1e8\",\"name\":\"Jim Phillips\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g\",\"caption\":\"Jim Phillips\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IEEE 1584 125 kVA Transformer Less than 240 Volts Exception","description":"IEEE 1584 Standard, IEEE Guide for Performing Arc-Flash Hazard Calculations, has an exception for circuits fed by 125 kVA transformers less than 240 volts.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/brainfiller.com\/es\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/","og_locale":"es_MX","og_type":"article","og_title":"IEEE 1584 125 kVA Transformer Less than 240 Volts Exception","og_description":"IEEE 1584 Standard, IEEE Guide for Performing Arc-Flash Hazard Calculations, has an exception for circuits fed by 125 kVA transformers less than 240 volts.","og_url":"https:\/\/brainfiller.com\/es\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/","og_site_name":"Arc Flash &amp; Electrical Power Training | Brainfiller","article_publisher":"https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","article_published_time":"2011-01-01T00:36:04+00:00","article_modified_time":"2025-11-21T21:24:53+00:00","og_image":[{"width":800,"height":528,"url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","type":"image\/jpeg"}],"author":"Jim Phillips","twitter_card":"summary_large_image","twitter_creator":"@brainfiller","twitter_site":"@brainfiller","twitter_misc":{"Escrito por":"Jim Phillips","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#article","isPartOf":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/"},"author":{"name":"Jim Phillips","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/4e1b5b26ff96ad8021b5886cc43de1e8"},"headline":"IEEE 1584 &#8211; 125 kVA Transformer \/ Less than 240 Volts Exception","datePublished":"2011-01-01T00:36:04+00:00","dateModified":"2025-11-21T21:24:53+00:00","mainEntityOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/"},"wordCount":209,"commentCount":0,"publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","keywords":["125 kVA exception","arc flash","arc flash calculations","arc flash study","IEEE 1584","jim phillips"],"articleSection":["Arc Flash and Electrical Safety","Brainfiller Library","Electrical Power Systems","NFPA 70E"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/","url":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/","name":"IEEE 1584 125 kVA Transformer Less than 240 Volts Exception","isPartOf":{"@id":"https:\/\/brainfiller.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#primaryimage"},"image":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#primaryimage"},"thumbnailUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","datePublished":"2011-01-01T00:36:04+00:00","dateModified":"2025-11-21T21:24:53+00:00","description":"IEEE 1584 Standard, IEEE Guide for Performing Arc-Flash Hazard Calculations, has an exception for circuits fed by 125 kVA transformers less than 240 volts.","breadcrumb":{"@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#primaryimage","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2025\/11\/brainfiller-brain-800x528-1.jpg","width":800,"height":528},{"@type":"BreadcrumbList","@id":"https:\/\/brainfiller.com\/brainfiller-library\/ieee-1584-125-kva-transformer-less-than-240-volts-exception\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/brainfiller.com\/"},{"@type":"ListItem","position":2,"name":"IEEE 1584 &#8211; 125 kVA Transformer \/ Less than 240 Volts Exception"}]},{"@type":"WebSite","@id":"https:\/\/brainfiller.com\/#website","url":"https:\/\/brainfiller.com\/","name":"Arc Flash & Electrical Power Training | Brainfiller","description":"Arc Flash &amp; Electrical Power Training by Jim Phillips","publisher":{"@id":"https:\/\/brainfiller.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/brainfiller.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/brainfiller.com\/#organization","name":"Rellenador de cerebros.com","url":"https:\/\/brainfiller.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/","url":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","contentUrl":"https:\/\/brainfiller.com\/wp-content\/uploads\/2015\/05\/Brain-Logo.jpg","width":128,"height":118,"caption":"Brainfiller.com"},"image":{"@id":"https:\/\/brainfiller.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/pages\/Brainfiller\/121692927901400","https:\/\/x.com\/brainfiller","https:\/\/www.linkedin.com\/in\/brainfiller","https:\/\/www.youtube.com\/user\/BrainfillerTV"]},{"@type":"Person","@id":"https:\/\/brainfiller.com\/#\/schema\/person\/4e1b5b26ff96ad8021b5886cc43de1e8","name":"Jim Phillips","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5cd793bb7815502a440e1ae87c6cda9ac1f2ab4ecf753822b5df6e209399a280?s=96&d=mm&r=g","caption":"Jim Phillips"}}]}},"ticketed":false,"_links":{"self":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/96","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/comments?post=96"}],"version-history":[{"count":0,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/posts\/96\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media\/46440"}],"wp:attachment":[{"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/media?parent=96"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/categories?post=96"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/brainfiller.com\/es\/wp-json\/wp\/v2\/tags?post=96"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}