Cargando Eventos

How to Perform an Arc Flash Study – IEEE 1584 – 16 Hours

2018 IEEE 1584 Major Changes

16 horas | 16 PDH | 1,6 CEU

In this 16 hour arc flash training class, Jim Phillips, P.E., takes you through the IEEE 1584 Standard.  He takes you behind the scenes and discusses the details of the standard’s development, walks you through the arc flash analysis calculations with his calculation worksheets and how the standard is is used in arc flash studies. Learn about electrode configurations, enclosure size adjustments, system modeling, and Jim’s insider view of how to perform an arc flash study.

How do the electrode configurations affect the arcing fault current and incident energy? Why does HCB solve a PPE issue that was first identified during an ejected arc test.

$995.00    Individual Registration
$746.25     4 or more – Save 25%

For Large Groups or to hold this class at your location: Call or email: Director del programa | 800.874.8883 | +1.480.275.7451

Lo que recibirás con esta clase en vivo:

  • 16 horas de Vivir Entrenamiento por Jim Phillips, PE
  • Discusión en profundidad sobre IEEE 1584, configuraciones de electrodos, cálculos y más, basada en la visión privilegiada de Jim.
  • Cuaderno encuadernado en espiral con más de 340 diapositivas
  • Hojas de trabajo de cálculo de arco eléctrico de Jim
  • Versión bajo demanda de esta clase que no caduca! $495.00 ¡Valor!
  • Certificate with 16 Hours of Continuing Education Credit
  • Preguntas y respuestas interactivas con Jim Phillips

Register for This Class

Tickets

The numbers below include tickets for this event already in your cart. Clicking "Get Tickets" will allow you to edit any existing attendee information as well as change ticket quantities.
Arc Flash Studies - IEEE 1584 | June 1 - 4 - 2026
Live Streaming with interactive Q&A over 4 days | June 1 - 4, 2026 BONUS: FREE access will be provided to the Online version of this course.
$ 995.00
Unlimited
Arc Flash Studies - IEEE 1584 | December 7 - 10 - 2026
Live Streaming with interactive Q&A over 4 days | December 7 - 10, 2026 BONUS: FREE access will be provided to the Online version of this course.
$ 995.00
Unlimited

Al finalizar esta clase programada EN VIVO, recibirás acceso a la versión completa a pedido para que puedas revisarla y consultarla en el futuro. ¡La versión a pedido nunca caducará!

Horario diario de transmisión en vivo

Dos sesiones de 2 horas por día

Una hora de descanso cada día

Hora del este

12:00 p. m. a 2:00 p. m., hora del este de EE. UU.
15:00 a 17:00 horas, hora del este de EE. UU.

Hora del Pacífico

9:00 a. m. a 11:00 a. m. (hora estándar del Pacífico)
12:00 p. m. a 2:00 p. m. (hora estándar del Pacífico)

Fecha límite de inscripción

Cinco días antes de la primera clase para recibir el material de la clase.

Prima

Se incluye acceso a la versión a pedido de esta clase.

Arc Flash assessment training PPE and Protection Arc Flash Study Training

Course Details

In this 16 hour arc flash hazard analysis training class, Jim Phillips, P.E., takes you through the IEEE 1584 Standard.  Jim walks you through the calculations with his calculation worksheets and how standard is is used in arc flash studies.  You will see calculation details and be able to evaluate the differences when changing parameters such as electrode configurations and enclosure sizes.

Highlights of the IEEE 1584 Standard:

  • Cinco configuraciones de electrodos diferentes para permitir un modelado más detallado
    • Vertical electrodes in a metal box/enclosure.
    • Electrodos verticales terminados en una barrera aislante en una caja/recinto metálico – VCCB
    • Electrodos horizontales en una caja o recinto metálico – HCB
    • Vertical electrodes in open air – VOA
    • Electrodos horizontales al aire libre – HOA
  • Enclosure types and sizes
  • Cálculo del factor de corrección del gabinete para ajustarlo a un tamaño de gabinete específico
  • Se ha eliminado el efecto de puesta a tierra.
  • An arcing current variation factor calculation
  • Cálculos realizados en 1 de 3 niveles de voltaje con interpolación al voltaje real
  • Se eliminó la excepción del transformador de 125 kVA

Each calculation is performed in 2 steps which includes an initial calculation based on one of three voltage levels and a second calculation interpolating to the specific system voltage.    What about the 2 second rule?  Jim discusses all this and much more.

Descuentos para grupos

Descuentos para grupos: ¿Necesita capacitar a su personal? Aproveche nuestros descuentos para capacitaciones grupales.

4 o más: Descuento 25% | 10 o más: Descuento 30% | Los grupos más grandes pueden calificar para ¡Mayores descuentos!

Llámanos para una propuesta.

Agenda – IEEE 1584 Arc Flash Training Class

16 horas | 16 PDH | 1,6 CEU
  • ARCO ELÉCTRICO Y OTROS PELIGROS ELÉCTRICOS
    Efectos fisiológicos, electrocución, daño tisular, daño a órganos internos, quemaduras, fibrilación, quemadura de segundo grado “curable”
  • CÓDIGOS Y NORMAS
    OSHA 29 CFR – Parte 1910, Subparte S, NFPA 70, Código Eléctrico Nacional®, 2018 NFPA 70E, (CSA Z462 para clases de Canadá) Norma para la seguridad eléctrica en el lugar de trabajo, 2018 IEEE Standard 1584™, Guía IEEE para realizar cálculos de riesgo de arco eléctrico, requisitos legales, responsabilidad
  •  IEEE 1584 – STANDARD DEVELOPMENT
    History of the Development of IEEE 1584, IEEE/NFPA Collaboration, Working Group and Project Team, Range of Applicability, Data Requirements, Study Process, Table of Results for the Arc Flash Study Report.
  • DINÁMICA DEL CIRCUITO DE ARCO ELÉCTRICO 
    Fallas de arco eléctrico frente a fallas de perno, efecto de la corriente en el tiempo de despeje del dispositivo de sobrecorriente, limitación de corriente, efecto del tamaño del transformador y la intensidad de la fuente
  • MODELADO DEL ESTUDIO DE ARCO ELÉCTRICO
    Una línea, datos, configuración del sistema, múltiples fuentes
  • DATOS DE LA COMPAÑÍA DE SERVICIOS ELÉCTRICOS
    ¿Qué datos se deben solicitar, corriente de falla mínima y máxima, por qué no utilizar cálculos de bus infinito, qué pasa si no se pueden obtener los datos?
  • OVERVIEW OF IEEE 1584
    Introduction and Summary of the Standard
  • CONFIGURACIONES DE ELECTRODOS
    VCB – Electrodos verticales en una caja/gabinete de metal, VCCB Electrodos verticales terminados en una barrera aislante en una caja/gabinete de metal, HCB – Electrodos horizontales en una caja/gabinete de metal, VOA – Electrodos verticales al aire libre, HOA – Electrodos horizontales al aire libre
  • CÁLCULOS DE CORRIENTE DE ARCO ELÉCTRICO POR CORTOCIRCUITO – BAJO VOLTAJE
    Cálculo de la corriente de arco media intermedia, cálculo de la corriente de arco final: interpolación para voltaje, coeficientes y datos
  • TAMAÑOS Y TIPOS DE CAJAS
    Nuevos recintos, tamaños y tipos, distancias entre huecos
  • CÁLCULOS DEL FACTOR DE CORRECCIÓN DEL TAMAÑO DEL GABINETE
    Determinación del factor de corrección para el tamaño del recinto. Recinto poco profundo frente a recinto típico
  • DISTANCIA DE TRABAJO
    Selección de la distancia de trabajo para los cálculos de energía incidente
  • DURACIÓN DEL ARCO
    Using Time Current Curves, 2 Second Cut Off, Arc Sustainability
  • CÁLCULOS DE ENERGÍA INCIDENTAL – BAJA TENSIÓN
    Cálculo de la energía incidente intermedia, cálculo de la energía incidente final: interpolación para voltaje, coeficientes y datos
  • CÁLCULOS DE LÍMITES DE ARCO ELÉCTRICO – BAJA TENSIÓN
    Cálculo del límite intermedio del arco eléctrico, cálculo del límite final del arco eléctrico: interpolación para voltaje, coeficientes y datos
  • FACTOR DE VARIACIÓN DE LA CORRIENTE DE ARCO
    Calculation the Arcing Current Variation Factor for Minimum Arcing Current
  • CÁLCULOS DE CORRIENTE DE ARCO ELÉCTRICO POR CORTOCIRCUITO – MEDIA TENSIÓN
    Cálculo de la corriente de arco media intermedia, cálculo de la corriente de arco final: interpolación para voltaje, coeficientes y datos
  • CÁLCULOS DE ENERGÍA INCIDENTAL – MEDIA TENSIÓN
    Cálculo de la energía incidente intermedia, cálculo de la energía incidente final: interpolación para voltaje, coeficientes y datos
  • CÁLCULOS DE LÍMITES DE ARCO ELÉCTRICO – MEDIA TENSIÓN
    Cálculo del límite intermedio del arco eléctrico, cálculo del límite final del arco eléctrico: interpolación para voltaje, coeficientes y datos
  • CÁLCULOS DE ARCO ELÉCTRICO EN CC  
    Características de VI, cálculos de resistencia de arco de CC, cálculos de energía incidente de CC, cálculos de arco abierto frente a arco de caja, hojas de cálculo, resolución de problemas
  • COMPARACIÓN DE MÉTODOS DE CÁLCULO Y CONFIGURACIONES
    Comparison or Results for VCB, VCCB, HCB
  • CONSEJOS DE MODELADO
    Selección de configuración de electrodos, tamaño de la carcasa y distancias entre electrodos
  • OTRAS MEDIDAS DE PELIGRO
    Luz, presión de explosión, presión de sonido
  • DETERMINACIÓN DEL EPI REQUISITOS A PARTIR DE CÁLCULOS DE ENERGÍA INCIDENTAL
    Uso de la energía incidente calculada para determinar los requisitos de EPP. Simplificación de la selección
  •  ETIQUETAS DE ADVERTENCIA DE ARCO ELÉCTRICO
    Simplificación de Jim para etiquetas de arco eléctrico para reducir o eliminar la necesidad de volver a etiquetar, requisitos mínimos, ubicaciones de las etiquetas, requisitos de ANSI Z535, energía incidente frente a EPP específico del sitio frente a clasificación de arco, palabras y colores de señalización

¿Preguntas?

Si tiene preguntas, desea obtener información sobre la inscripción o desea analizar la posibilidad de realizar esta clase en su ubicación como un programa de capacitación en el sitio, comuníquese con nosotros.

Brainfiller, Inc. | Apartado Postal 12024 | Scottsdale, AZ 85267