Technical Articles

Technical Articles - Page 10 of 14 - Arc Flash & Electrical Power Training | Brainfiller

Orange and gray Brainfiller symbol

Global Use of IEEE 1584

The surface area of the earth is approximately 197 million square miles, and IEEE 1584—IEEE Guide for Performing Arc-Flash Hazard Calculations has been covering more of it every day since it was first published almost 11 years ago. Although the IEEE 1584 standard has its roots in the United States, it has gained widespread international use as the most common method for performing arc flash calculation studies.

Read More »
Orange and gray Brainfiller symbol

IEEE 1584 Revision Update – 201X Edition

IEEE 1584 – Where It All Began – 2002 A lot has happened since 2002 when IEEE 1584 – IEEE Guide for Arc-Flash Hazard Calculations was first published. The development of this land mark document included conducting over 300 arc flash tests which were used to create the empirically derived equations. Applicable for three phase calculations and voltages ranging from 208 volts to 15,000 volts, four main calculation methods are the backbone of this standard and include: • Arcing short

Read More »
Call Before You Dig 811 logo

Happy August 11! (and call before you dig)

Happy August 11! (and call before you dig): Today is a special day. August 11 – Also known as 8 11 (unless you use the format day/month) What is so special about 811? 8-1-1 is the telephone number that you use to find underground utilities before you dig.

Read More »
Warning Label - Arc Flash Shock Hazard Appropriate PPE Required

Arc Flash Labels – Simplified!

“What do you mean we need to relabel the electrical equipment? Didn’t we just do this a few years ago?” This is a pretty common response when addressing the requirements of NFPA 70E 130.5(2), which necessitate that the arc-flash risk…

Read More »
Orange and gray Brainfiller symbol

Wind and Solar Electrical Safety

Wind and Solar Electrical Safety – Rising to the Occasion – A few months ago I was driving home from the Los Angeles area and suddenly found myself surrounded by thousands of wind turbines lining both sides of Interstate 10. Even though I have made this trip many times before, I am still in awe at the scale of it all. Looking through my

Read More »
Orange and gray Brainfiller symbol

Working Distance Mistakes in an Arc Flash Study

The term “working distance” appears 20 times in the 2012 Edition of NFPA 70E, the Standard for Electrical Safety in the Workplace. It appears 12 more times in the annexes. The working distance is an important component of the arc flash hazard analysis and is frequently listed on arc flash warning labels and in the arc flash report. IEEE 1584—IEEE Guide for Performing Arc Flash Hazard Calculations 2002 defines the working distance as “the dimension between the possible arc point and the head

Read More »
FREE Download Arc Flash Hazard Calculation Guide

How to Perform an Arc Flash Study

How to Perform an Arc Flash Study: What started as a slow drip a decade ago has turned into something more like a tidal wave. I’m not talking about a leaky faucet or a failing dam; I am referring to arc flash studies. Years ago, only a…

Read More »
Setting up the electrical enclosure

Arc Flash Hazard Calculation Studies

In the earlier years of NFPA 70E and the emergence of arc flash protection requirements, many people would use the NFPA 70E Hazard/Risk Tables to determine what arc rated PPE to wear. This approach continues to shift towards the use…

Read More »